Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
- Featured-Product
ELISA Kit for Macrophage Inflammatory Protein 4 Alpha (MIP4a)
CCL26; SCYA26; IMAC; TSC-1; Eotaxin 3; Thymic stroma chemokine-1; Chemokine(C-C-Motif)ligand 26; Thymic Stroma Chemokine-1; Small Inducible Cytokine Subfamily A 26
- Product No.SEC091Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range15.6-1,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 5.6pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 333
For more details, please contact local distributors! US$ 475 US$ 2138 US$ 4038 US$ 33250
Specificity
This assay has high sensitivity and excellent specificity for detection of Macrophage Inflammatory Protein 4 Alpha (MIP4a).
No significant cross-reactivity or interference between Macrophage Inflammatory Protein 4 Alpha (MIP4a) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Macrophage Inflammatory Protein 4 Alpha (MIP4a) and the recovery rates were calculated by comparing the measured value to the expected amount of Macrophage Inflammatory Protein 4 Alpha (MIP4a) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-101 | 95 |
EDTA plasma(n=5) | 87-104 | 99 |
heparin plasma(n=5) | 94-103 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Macrophage Inflammatory Protein 4 Alpha (MIP4a) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Macrophage Inflammatory Protein 4 Alpha (MIP4a) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Macrophage Inflammatory Protein 4 Alpha (MIP4a) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-96% | 85-97% | 96-103% | 82-95% |
EDTA plasma(n=5) | 91-99% | 87-104% | 80-101% | 85-94% |
heparin plasma(n=5) | 91-98% | 94-102% | 83-93% | 94-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Adv Med Sci | Association of eosinophil-mediated inflammatory biomarkers with the presence of the Schatzki ring 34091432 |
biomolecules | Searching for Noninvasive Predictors of the Diagnosis and Monitoring of Eosinophilic Esophagitis¡ªThe Importance of Biomarkers of the Inflammatory Reaction?¡ |