Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Cathepsin S (CTSS)
CTS-S
- Product No.SEB933Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range62.5-4,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 23.9pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 505
For more details, please contact local distributors! US$ 722 US$ 3249 US$ 6137 US$ 50540
Specificity
This assay has high sensitivity and excellent specificity for detection of Cathepsin S (CTSS).
No significant cross-reactivity or interference between Cathepsin S (CTSS) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Cathepsin S (CTSS) and the recovery rates were calculated by comparing the measured value to the expected amount of Cathepsin S (CTSS) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 87-101 | 95 |
EDTA plasma(n=5) | 80-93 | 87 |
heparin plasma(n=5) | 97-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cathepsin S (CTSS) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cathepsin S (CTSS) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cathepsin S (CTSS) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-92% | 91-99% | 80-89% | 80-97% |
EDTA plasma(n=5) | 86-101% | 80-104% | 95-103% | 93-101% |
heparin plasma(n=5) | 79-90% | 97-105% | 90-104% | 85-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Chinses Medical Journal | Relationship between plasma cathepsin S and cystatin C levels and coronary plaque morphology of mild to moderate lesions: an in vivo study using intravascular ultrasound CMJ: 2009124346863507950 |
Journal of Cystic Fibrosis | Protease–antiprotease imbalances differ between Cystic Fibrosis patients' upper and lower airway secretions Pubmed:25286826 |
Scientific Reports | Circulating cathepsin-S levels correlate with GFR decline and sTNFR1 and sTNFR2 levels in mice and humans. pubmed:28240259 |
Neuroscience | The P2X7 receptor, cathepsin S and fractalkine in the trigeminal subnucleus caudalis signal persistent hypernociception in temporomandibular rat joints Pubmed: 30248434 |
TOXICON | Modulatory effect of botulinum toxin type A on the microglial P2X7/CatS/FKN activated-pathway in antigen-induced arthritis of the temporomandibular joint of … Pubmed: 32882256 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPB933Ra01 | Recombinant Cathepsin S (CTSS) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB933Ra01 | Polyclonal Antibody to Cathepsin S (CTSS) | WB; IHC; ICC; IP. |
MAB933Ra21 | Monoclonal Antibody to Cathepsin S (CTSS) | WB; IHC; ICC; IP. |
SEB933Ra | ELISA Kit for Cathepsin S (CTSS) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB933Ra | Multiplex Assay Kit for Cathepsin S (CTSS) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |