ELISA Kit for Troponin T (TNT)

Tn-T; TNNT

Specificity

This assay has high sensitivity and excellent specificity for detection of Troponin T (TNT).
No significant cross-reactivity or interference between Troponin T (TNT) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Troponin T (TNT) and the recovery rates were calculated by comparing the measured value to the expected amount of Troponin T (TNT) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-92 82
EDTA plasma(n=5) 97-104 101
heparin plasma(n=5) 78-92 86

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Troponin T (TNT) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Troponin T (TNT) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Troponin T (TNT) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-96% 95-102% 94-102% 85-105%
EDTA plasma(n=5) 81-97% 79-94% 85-94% 82-98%
heparin plasma(n=5) 78-101% 78-89% 97-105% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
IJC Heart & Vasculature Cardiovascular changes in patients with non-severe Plasmodium vivax malaria article:S2352-9067(16)30010-0
Journal of the American Heart Association Postinfarction Hearts Are Protected by Premature Senescent Cardiomyocytes Via GATA 4‐Dependent CCN 1 Secretion
Experimental Gerontology Neural control of postural sway: relationship to strength measures in young and elderly adults Pubmed: 30630036
Nature Communications Preclinical development of a miR-132 inhibitor for heart failure treatment Pubmed: 32005803
Scientific Reports Cardioprotective effect of grape polyphenol extract against doxorubicin induced cardiotoxicity Pubmed: 32895481
Molecular Medicine Reports The mRNA expression of Il6 and Pdcd1 are predictive and protective factors for doxorubicin?induced cardiotoxicity 33300057
Cell Metabolism Pharmacological inhibition of arachidonate 12-lipoxygenase ameliorates myocardial ischemia-reperfusion injury in multiple species 34536344
Catalog No. Related products for research use of Sus scrofa; Porcine (Pig) Organism species Applications (RESEARCH USE ONLY!)
SEB820Po ELISA Kit for Troponin T (TNT) Enzyme-linked immunosorbent assay for Antigen Detection.