ELISA Kit for Neprilysin (CD10)
NEP; MME; CALLA; SFE; Atriopeptidase; Enkephalinase; Skin fibroblast elastase; Common Acute Lymphoblastic Leukemia Antigen; Membrane Metallo-Endopeptidase
- Product No.SEB785Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, cerebrospinal fluid, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range31.2-2,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 12.1pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 466
For more details, please contact local distributors! US$ 665 US$ 2993 US$ 5653 US$ 46550
Specificity
This assay has high sensitivity and excellent specificity for detection of Neprilysin (CD10).
No significant cross-reactivity or interference between Neprilysin (CD10) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Neprilysin (CD10) and the recovery rates were calculated by comparing the measured value to the expected amount of Neprilysin (CD10) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-98 | 89 |
EDTA plasma(n=5) | 85-104 | 97 |
heparin plasma(n=5) | 81-96 | 85 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neprilysin (CD10) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neprilysin (CD10) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Neprilysin (CD10) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-104% | 90-99% | 82-94% | 98-105% |
EDTA plasma(n=5) | 86-94% | 78-102% | 84-101% | 80-103% |
heparin plasma(n=5) | 78-92% | 91-98% | 91-105% | 79-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
13 | Elevated Plasma levels of Neutral Endpeptidase in Hypertension Patients Treated with Angiotensin Converting Enzyme Inhibitors Ahajournals:Source |
Biol Pharm Bull | Effect of High Glucose Levels on Amyloid β Production in Retinas of Spontaneous Diabetes Mellitus Otsuka Long-Evans Tokushima Fatty Rats PubMed: 25832640 |
Eur J Heart Fail. | Soluble neprilysin does not correlate with outcome in heart failure with preserved ejection fraction Pubmed:26725876 |
8 | A Test in Context: Neprilysin: Function, Inhibition, and Biomarker. pubmed:27491909 |
European Journal of Heart Failure | Effects of sacubitril/valsartan on neprilysin targets and the metabolism of natriuretic peptides in chronic heart failure: a mechanistic clinical study Pubmed: 30520545 |
European Journal of Heart Failure | Increased granulocyte membrane neprilysin (CD10) expression is associated with better prognosis in heart failure Pubmed: 30828920 |
Clinical Research in Cardiology | Soluble neprilysin, NT-proBNP, and growth differentiation factor-15 as biomarkers for heart failure in dialysis patients (SONGBIRD) Pubmed: 32002632 |
Neurotoxicology | Involvement of hippocampal agmatine in β1-42 amyloid induced memory impairment, neuroinflammation and BDNF signaling disruption in mice Pubmed: 32522471 |
European Heart Journal | P1620 Association of granulocyte neprilysin (CD10) expression with prognosis in heart failure with reduced ejection fraction |
Clin Biochem | Finding a reliable assay for soluble neprilysin Pubmed:35331754 |
Scientific Reports | The potential role of serum tau protein (MAPT), neuronal cell adhesion molecule (NrCAM) and neprilysin (NEP) in neurodegenerative disorders development in … |