ELISA Kit for N-cadherin (NCAD)
CDw325; CD325; CDHN; CDH2; Cadherin 2 Type 1; N-Cadherin
- Product No.SEB481Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.156-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.057ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 466
For more details, please contact local distributors! US$ 665 US$ 2993 US$ 5653 US$ 46550
Specificity
This assay has high sensitivity and excellent specificity for detection of N-cadherin (NCAD).
No significant cross-reactivity or interference between N-cadherin (NCAD) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant N-cadherin (NCAD) and the recovery rates were calculated by comparing the measured value to the expected amount of N-cadherin (NCAD) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 98-105 | 102 |
EDTA plasma(n=5) | 80-93 | 89 |
heparin plasma(n=5) | 78-96 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level N-cadherin (NCAD) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level N-cadherin (NCAD) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of N-cadherin (NCAD) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 85-102% | 85-101% | 79-104% | 78-105% |
EDTA plasma(n=5) | 92-103% | 95-102% | 96-105% | 93-101% |
heparin plasma(n=5) | 97-104% | 96-103% | 83-104% | 99-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Toxicology Letters | Biomarkers for methotrexate-induced liver injury: urinary protein profiling of psoriasis patients. Pubmed: 23830989 |
British journal of haematology | Circulating N-cadherin levels are a negative prognostic indicator in patients with multiple myeloma. Pubmed: 23438504 |
JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY | Elevated Cerebrospinal Fluid and Plasma N-Cadherin in Alzheimer Disease Pubmed: 32296844 |
Cell Biol Toxicol | ZNF471 modulates EMT and functions as methylation regulated tumor suppressor with diagnostic and prognostic significance in cervical cancer 33566221 |
CELL BIOLOGY AND TOXICOLOGY | Metastatic suppression by DOC2B is mediated by inhibition of epithelial-mesenchymal transition and induction of senescence 33758996 |
Pharmacol Res | DOC2B is a Negative Regulator of Wnt/β-catenin Signaling Pathway in Cervical Cancer Pubmed:35500882 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPB481Hu02 | Recombinant N-cadherin (NCAD) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPB481Hu01 | Recombinant N-cadherin (NCAD) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB481Hu01 | Polyclonal Antibody to N-cadherin (NCAD) | WB; IHC; ICC; IP. |
PAB481Hu02 | Polyclonal Antibody to N-cadherin (NCAD) | WB; IHC; ICC; IP. |
LAB481Hu71 | Biotin-Linked Polyclonal Antibody to N-cadherin (NCAD) | WB; IHC; ICC. |
MAB481Hu22 | Monoclonal Antibody to N-cadherin (NCAD) | WB; IHC; ICC; IP. |
SEB481Hu | ELISA Kit for N-cadherin (NCAD) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB481Hu | Multiplex Assay Kit for N-cadherin (NCAD) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |