ELISA Kit for Semaphorin 7A (SEMA7A)
CD108; CDw108; H-SEMA-K1; H-Sema-L; JMH; SEMAK1; SEMAL; Semaphorin 7A,GPI Membrane Anchor; John Milton Hagen Blood Group; Semaphorin-K1; Semaphorin-L
- Product No.SEB448Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.312-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.113ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 479
For more details, please contact local distributors! US$ 684 US$ 3078 US$ 5814 US$ 47880
Specificity
This assay has high sensitivity and excellent specificity for detection of Semaphorin 7A (SEMA7A).
No significant cross-reactivity or interference between Semaphorin 7A (SEMA7A) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Semaphorin 7A (SEMA7A) and the recovery rates were calculated by comparing the measured value to the expected amount of Semaphorin 7A (SEMA7A) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-105 | 101 |
EDTA plasma(n=5) | 78-103 | 85 |
heparin plasma(n=5) | 87-94 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Semaphorin 7A (SEMA7A) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Semaphorin 7A (SEMA7A) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Semaphorin 7A (SEMA7A) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-95% | 86-94% | 83-97% | 78-101% |
EDTA plasma(n=5) | 89-97% | 78-104% | 90-105% | 80-97% |
heparin plasma(n=5) | 88-95% | 98-105% | 80-101% | 80-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
PLOS ONE | Semaphorin 7A Aggravates Pulmonary Inflammation during Lung Injury pmc:PMC4720127 |
Experimental and Therapeutic Medicine | Anti-Semaphorin-7A single chain antibody demonstrates beneficial effects on pulmonary inflammation during acute lung injury Pubmed:29456642 |
Nature Communications | Red blood cell-derived semaphorin 7A promotes thrombo-inflammation in myocardial ischemia-reperfusion injury through platelet GPIb Pubmed: 32161256 |
American Journal of Hematology | Semaphorin 7A: A novel marker of disease activity in Gaucher disease Pubmed: 31990411 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPB448Mu02 | Recombinant Semaphorin 7A (SEMA7A) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPB448Mu01 | Recombinant Semaphorin 7A (SEMA7A) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB448Mu01 | Polyclonal Antibody to Semaphorin 7A (SEMA7A) | WB; IHC; ICC; IP. |
PAB448Mu02 | Polyclonal Antibody to Semaphorin 7A (SEMA7A) | WB; IHC; ICC; IP. |
SEB448Mu | ELISA Kit for Semaphorin 7A (SEMA7A) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB448Mu | Multiplex Assay Kit for Semaphorin 7A (SEMA7A) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |