ELISA Kit for Glucose Transporter 1 (GLUT1)

SLC2A1; SLC2-A1; GLUT; Solute Carrier Family 2 Member 1,Facilitated Glucose Transporter; Glucose transporter type 1, erythrocyte/brain; HepG2 glucose transporter

Specificity

This assay has high sensitivity and excellent specificity for detection of Glucose Transporter 1 (GLUT1).
No significant cross-reactivity or interference between Glucose Transporter 1 (GLUT1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glucose Transporter 1 (GLUT1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glucose Transporter 1 (GLUT1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biosensors Single Step Nanoplasmonic Immunoassay for the Measurement of Protein Biomarkers Mdpi: Source
Neurotoxicity Research N-Acetylcysteine and Ceftriaxone as Preconditioning Strategies in Focal Brain Ischemia: Influence on Glutamate Transporters Expression Pubmed:26861954
Scientific Reports Oral formulation of DPP-4 inhibitor plus Quercetin improves metabolic homeostasis in type 1 diabetic rats Pubmed: 30333575
Neurotoxicity Research Brain Metabolic Alterations in Rats Showing Depression-Like and Obesity Phenotypes Pubmed: 31782099
Comparative study about ageing effect on retina and cerebellum of Columba livia domestica
Chrysin serves as a novel inhibitor of DGKα/FAK interaction to suppress the malignancy of esophageal squamous cell carcinoma (ESCC)
J Cell Mol Med Huaier shows anti©\cancer activities by inhibition of cell growth, migration and energy metabolism in lung cancer through PI3K/AKT/HIF©\1¦Á pathway 33377619
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB185Hu02 Recombinant Glucose Transporter 1 (GLUT1) Positive Control; Immunogen; SDS-PAGE; WB.
RPB185Hu01 Recombinant Glucose Transporter 1 (GLUT1) Positive Control; Immunogen; SDS-PAGE; WB.
CPB185Hu21 OVA Conjugated Glucose Transporter 1 (GLUT1) Immunogen; SDS-PAGE; WB.
PAB185Hu01 Polyclonal Antibody to Glucose Transporter 1 (GLUT1) WB
PAB185Hu02 Polyclonal Antibody to Glucose Transporter 1 (GLUT1) WB; IHC; ICC; IP.
LAB185Hu71 Biotin-Linked Polyclonal Antibody to Glucose Transporter 1 (GLUT1) WB; IHC; ICC.
MAB185Hu22 Monoclonal Antibody to Glucose Transporter 1 (GLUT1) WB,IHC
MAB185Hu23 Monoclonal Antibody to Glucose Transporter 1 (GLUT1) WB
MAB185Hu21 Monoclonal Antibody to Glucose Transporter 1 (GLUT1) WB
SEB185Hu ELISA Kit for Glucose Transporter 1 (GLUT1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB185Hu Multiplex Assay Kit for Glucose Transporter 1 (GLUT1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.