ELISA Kit for Ischemia Modified Albumin (IMA)

Specificity

This assay has high sensitivity and excellent specificity for detection of Ischemia Modified Albumin (IMA).
No significant cross-reactivity or interference between Ischemia Modified Albumin (IMA) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Ischemia Modified Albumin (IMA) and the recovery rates were calculated by comparing the measured value to the expected amount of Ischemia Modified Albumin (IMA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-99 95
EDTA plasma(n=5) 86-101 90
heparin plasma(n=5) 91-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ischemia Modified Albumin (IMA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ischemia Modified Albumin (IMA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ischemia Modified Albumin (IMA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-94% 87-95% 99-105% 97-105%
EDTA plasma(n=5) 98-105% 98-105% 91-99% 97-104%
heparin plasma(n=5) 78-101% 80-102% 96-103% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Aging Clin Exp Res The role of protein oxidation and DNA damage in elderly hypertension PubMed: 26487663
The Anatolian Journal of Cardiology The impact of protein oxidation on sustained and white coat hypertension pubmed:27684518
Indian Journal of Thoracic and Cardiovascular Surgery Investigation of serum ischemia-modified albumin levels in coronary artery disease patients
Journal of Cardiovascular Medicine Effects of Different Heart Positions During Off-pump Coronary Artery Bypass Surgery on Serum Ischemia Modified Albumin Level and Cardiac Output
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
SEA825Mu ELISA Kit for Ischemia Modified Albumin (IMA) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA825Mu ELISA Kit for Ischemia Modified Albumin (IMA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA825Mu Multiplex Assay Kit for Ischemia Modified Albumin (IMA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA825Mu11 ELISA Kit DIY Materials for Ischemia Modified Albumin (IMA) Main materials for "Do It (ELISA Kit) Yourself".