• Featured-Product
ELISA Kit for Stem Cell Factor (SCF)

KITLG; MGF; SF; KL1; Kitl; FPH2; Kit-Ligand; Steel Factor; Mast Cell Growth Factor; Steel factor; Familial Progressive Hyperpigmentation 2

Specificity

This assay has high sensitivity and excellent specificity for detection of Stem Cell Factor (SCF).
No significant cross-reactivity or interference between Stem Cell Factor (SCF) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Stem Cell Factor (SCF) and the recovery rates were calculated by comparing the measured value to the expected amount of Stem Cell Factor (SCF) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-105 96
EDTA plasma(n=5) 83-95 90
heparin plasma(n=5) 97-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Stem Cell Factor (SCF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Stem Cell Factor (SCF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Stem Cell Factor (SCF) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-104% 96-105% 94-102% 79-95%
EDTA plasma(n=5) 88-95% 78-101% 83-101% 98-105%
heparin plasma(n=5) 78-104% 91-98% 84-93% 93-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Archives of Gynecology and Obstetrics Effect of ovarian stimulation with recombinant follicle-stimulating hormone, gonadotropin-releasing hormone agonist and antagonists, on follicular fluid stem cell factor and serum urocortin 1 levels on the day of oocyte retrieval Pubmed: 23801011
Medicine (Baltimore) An Attempt to Evaluate Selected Aspects of “Bone–Fat Axis” Function in Healthy Individuals and Patients With Pancreatic Cancer PubMed: 26266370
Tumor Biology Hypoxia-induced secretion of IL-13 from adipose-derived mesenchymal stem cell promotes growth and cancer stem cell properties of Burkitt lymphoma PubMed: 26695151
Molecular Neurobiology Middle-Aged Diabetic Females and Males Present Distinct Susceptibility to Alzheimer Disease-like Pathology. pubmed:27730513
Oncotarget Nucleoside reverse transcriptase inhibitor-induced rat oocyte dysfunction and low fertility mediated by autophagy Pubmed:29423092
Journal of Environmental Research and Public Health Effects of 220 MHz Pulsed Modulated Radiofrequency Field on the Sperm Quality in Rats Pubmed: 30974849
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA120Hu02 Recombinant Stem Cell Factor (SCF) Positive Control; Immunogen; SDS-PAGE; WB.
APA120Hu61 Active Stem Cell Factor (SCF) Cell culture; Activity Assays.
EPA120Hu61 Eukaryotic Stem Cell Factor (SCF) Positive Control; Immunogen; SDS-PAGE; WB.
APA120Hu62 Active Stem Cell Factor (SCF) Cell culture; Activity Assays.
RPA120Hu01 Recombinant Stem Cell Factor (SCF) Positive Control; Immunogen; SDS-PAGE; WB.
APA120Hu01 Active Stem Cell Factor (SCF) Cell culture; Activity Assays.
PAA120Hu01 Polyclonal Antibody to Stem Cell Factor (SCF) WB; IHC; ICC; IP.
MAA120Hu22 Monoclonal Antibody to Stem Cell Factor (SCF) WB; IHC; ICC; IP.
MEA120Hu Mini Samples ELISA Kit for Stem Cell Factor (SCF) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA120Hu ELISA Kit for Stem Cell Factor (SCF) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA120Hu CLIA Kit for Stem Cell Factor (SCF) Chemiluminescent immunoassay for Antigen Detection.
LMA120Hu Multiplex Assay Kit for Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA120Hu01 ELISA Kit DIY Materials for Stem Cell Factor (SCF) Main materials for "Do It (ELISA Kit) Yourself".