Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Inhibin Beta E (INHbE)
INH-bE; Activin beta-E chain
- Product No.SEA048Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range15.6-1,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 5.7pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 441
For more details, please contact local distributors! US$ 630 US$ 2835 US$ 5355 US$ 44100
Specificity
This assay has high sensitivity and excellent specificity for detection of Inhibin Beta E (INHbE).
No significant cross-reactivity or interference between Inhibin Beta E (INHbE) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Inhibin Beta E (INHbE) and the recovery rates were calculated by comparing the measured value to the expected amount of Inhibin Beta E (INHbE) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 98-105 | 102 |
EDTA plasma(n=5) | 94-102 | 98 |
heparin plasma(n=5) | 95-102 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inhibin Beta E (INHbE) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inhibin Beta E (INHbE) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inhibin Beta E (INHbE) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-89% | 94-101% | 80-103% | 80-96% |
EDTA plasma(n=5) | 83-104% | 83-94% | 80-92% | 86-95% |
heparin plasma(n=5) | 79-95% | 97-105% | 98-105% | 90-97% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Mitochondrion | GDF15 is a novel biomarker to evaluate efficacy of pyruvate therapy for mitochondrial diseases Pubmed:25446397 |
PLoS One | Inhibin βE (INHBE) is a possible insulin resistance-associated hepatokine identified by comprehensive gene expression analysis in human liver biopsy … Pubmed:29596463 |
Cell Reports | Activin E Controls Energy Homeostasis in Both Brown and White Adipose Tissues as a Hepatokine Pubmed: 30380411 |
International Journal of Pharmacy and Biological Sciences | Anti-Obesity Efficacy of Selected Plants Against Progesterone Induced Obesity |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPA048Hu01 | Recombinant Inhibin Beta E (INHbE) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA048Hu01 | Polyclonal Antibody to Inhibin Beta E (INHbE) | WB; IHC; ICC; IP. |
LAA048Hu71 | Biotin-Linked Polyclonal Antibody to Inhibin Beta E (INHbE) | WB; IHC; ICC. |
LAA048Hu81 | FITC-Linked Polyclonal Antibody to Inhibin Beta E (INHbE) | WB; IHC; ICC; IF. |
MAA048Hu22 | Monoclonal Antibody to Inhibin Beta E (INHbE) | WB; IHC; ICC; IP. |
SEA048Hu | ELISA Kit for Inhibin Beta E (INHbE) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA048Hu | ELISA Kit for Inhibin Beta E (INHbE) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA048Hu | CLIA Kit for Inhibin Beta E (INHbE) | Chemiluminescent immunoassay for Antigen Detection. |
LMA048Hu | Multiplex Assay Kit for Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA048Hu01 | ELISA Kit DIY Materials for Inhibin Beta E (INHbE) | Main materials for "Do It(ELISA Kit) Yourself" |