Packages (Simulation)
Reagent Preparation
Image (I)
Certificate
CLIA Kit for Cluster Of Differentiation 146 (CD146)
MCAM; MUC18; Melanoma Cell Adhesion Molecule; Cell surface glycoprotein P1H12; Melanoma-associated antigen A32; S-endo 1 endothelial-associated antigen
- Product No.SCB670Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length2h, 40min
- Detection Range54.9-40,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 22.9pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 605
For more details, please contact local distributors! US$ 864 US$ 3888 US$ 7344 US$ 60480
Specificity
This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 146 (CD146).
No significant cross-reactivity or interference between Cluster Of Differentiation 146 (CD146) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Cluster Of Differentiation 146 (CD146) and the recovery rates were calculated by comparing the measured value to the expected amount of Cluster Of Differentiation 146 (CD146) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 98-105 | 101 |
EDTA plasma(n=5) | 89-101 | 94 |
heparin plasma(n=5) | 81-101 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 146 (CD146) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 146 (CD146) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cluster Of Differentiation 146 (CD146) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 83-101% | 91-99% | 93-101% | 90-97% |
EDTA plasma(n=5) | 87-97% | 83-90% | 80-91% | 80-94% |
heparin plasma(n=5) | 93-101% | 78-92% | 97-105% | 91-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- CLIA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Clinical Rheumatology | Evaluation of various endothelial biomarkers in ankylosing spondylitis PubMed: 21556780 |
Inflammation | The Effect of Regular Colchicine Treatment on Biomarkers Related with Vascular Injury in Newly Diagnosed Patients with Familial Mediterranean Fever SpringerLink: m7128503g576w808 |
Oncotarget | Selective targeting of liver cancer with the endothelial marker CD146 Pubmed:25238265 |
Future Medicine | Melanoma cell adhesion molecule as an emerging biomarker with prognostic significance in systolic heart failure pubmed:27355366 |