Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
CLIA Kit for Fibrinogen (FG)
F1; FI; Fbg; Coagulation Factor I
- Product No.SCA193Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypePlasma
- Test MethodDouble-antibody Sandwich
- Assay Length2h, 40min
- Detection Range2.74-2,000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 1.35ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 588
For more details, please contact local distributors! US$ 840 US$ 3780 US$ 7140 US$ 58800
Specificity
This assay has high sensitivity and excellent specificity for detection of Fibrinogen (FG).
No significant cross-reactivity or interference between Fibrinogen (FG) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Fibrinogen (FG) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibrinogen (FG) in samples.
Matrix | Recovery range (%) | Average(%) |
sodium citrate plasma(n=5) | 85-103 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibrinogen (FG) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibrinogen (FG) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibrinogen (FG) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
sodium citrate plasma(n=5) | 96-103% | 99-105% | 87-97% | 93-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Chemical Research in Toxicology | Sub-chronic Toxicity and Cardiovascular Responses in Spontaneously Hypertensive Rats after Exposure to Multiwall Carbon Nanotubes by Intratracheal Instillation Pubmed:25580880 |
Chemical Research in Toxicology | Subchronic Toxicity and Cardiovascular Responses in Spontaneously Hypertensive Rats after Exposure to Multiwalled Carbon Nanotubes by Intratracheal Instillation PubMed: 25580880 |
VETERINARSKI ARHIV | Biomarkers of ketosis in dairy cows at postparturient period: acute phase proteins and pro-inflammatory cytokines doi: 10.24099/vet.arhiv.160126c |
VETERINARSKI ARHIV | Biomarkeri ketoze u mliječnih krava u postpartalnom razdoblju: proteini akutne faze i proupalni citokini doi: 10.24099/vet.arhiv.160126c |
Spike protein up-regulates inflammatory axis of both thromboinflammation and leukotriene in severe COVID-19 | |
Toxicol Appl Pharmacol | CREB1 protects against the renal injury in a rat model of kidney stone disease and calcium oxalate monohydrate crystals-induced injury in NRK-52E cells 33421503 |
large animal review | Influence of niacin application on inflammatory parameters, non-esterified fatty acids and functional status of liver in cows during early lactation |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
NPA193Hu01 | Native Fibrinogen (FG) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA193Hu01 | Polyclonal Antibody to Fibrinogen (FG) | WB; IHC; ICC; IP. |
PAA193Hu05 | Polyclonal Antibody to Fibrinogen (FG) | WB; IHC; ICC; IP. |
LAA193Hu71 | Biotin-Linked Polyclonal Antibody to Fibrinogen (FG) | WB; IHC; ICC. |
LAA193Hu81 | FITC-Linked Polyclonal Antibody to Fibrinogen (FG) | WB; IHC; ICC; IF. |
MAA193Hu21 | Monoclonal Antibody to Fibrinogen (FG) | WB; IHC; ICC; IP. |
MAA193Hu22 | Monoclonal Antibody to Fibrinogen (FG) | WB; IHC; ICC; IP. |
SEA193Hu | ELISA Kit for Fibrinogen (FG) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA193Hu | ELISA Kit for Fibrinogen (FG) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA193Hu | CLIA Kit for Fibrinogen (FG) | Chemiluminescent immunoassay for Antigen Detection. |
LMA193Hu | Multiplex Assay Kit for Fibrinogen (FG) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA193Hu01 | ELISA Kit DIY Materials for Fibrinogen (FG) | Main materials for "Do It(ELISA Kit) Yourself" |