Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Mini Samples ELISA Kit for Claudin 5 (CLDN5)
AWAL; BEC1; CPETRL1; TMVCF; Transmembrane Protein Deleted In Velocardiofacial Syndrome; Transmembrane protein deleted in VCFS
- Product No.MEF295Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range31.2-2,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 13.5pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 588
For more details, please contact local distributors! US$ 840 US$ 3780 US$ 7140 US$ 58800
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples Claudin 5 (CLDN5).
No significant cross-reactivity or interference between Mini Samples Claudin 5 (CLDN5) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Mini Samples Claudin 5 (CLDN5) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Claudin 5 (CLDN5) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 99-105 | 102 |
EDTA plasma(n=5) | 84-97 | 89 |
heparin plasma(n=5) | 97-105 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Claudin 5 (CLDN5) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Claudin 5 (CLDN5) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Claudin 5 (CLDN5) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-99% | 92-105% | 86-94% | 78-101% |
EDTA plasma(n=5) | 91-101% | 98-105% | 97-104% | 89-98% |
heparin plasma(n=5) | 88-102% | 94-101% | 88-102% | 89-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×60µL | Assay Diluent A | 1×6mL |
Detection Reagent B | 1×60µL | Assay Diluent B | 1×6mL |
TMB Substrate | 1×4.5mL | Stop Solution | 1×3mL |
Wash Buffer (30 × concentrate) | 1×10mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
ALLERGY ASTHMA & IMMUNOLOGY RESEARCH | The Impact of the Endothelial Tight Junction Protein, Claudin-5, on the Clinical Profiles of Patients With COPD Pubmed:30088372 |
Int J Psychiatry Clin Pract | Serum zonulin and claudin-5 levels in children with attention-deficit/hyperactivity disorder Pubmed: 32757874 |
Eur Arch Psychiatry Clin Neurosci | Serum zonulin and claudin-5 levels in patients with schizophrenia Pubmed: 32564127 |
BIPOLAR DISORDERS | Regulatory effect of lithium on hippocampal blood‐brain barrier integrity in a rat model of depressive‐like behavior Pubmed: 32558151 |
J Paediatr Child Health | Zonulin and claudin‐5 levels in multisystem inflammatory syndrome and SARS‐CoV‐2 infection in children Pubmed:35638118 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPF295Hu01 | Recombinant Claudin 5 (CLDN5) | Positive Control; Immunogen; SDS-PAGE; WB. |
CPF295Hu21 | OVA Conjugated Claudin 5 (CLDN5) | Immunogen; SDS-PAGE; WB. |
PAF295Hu01 | Polyclonal Antibody to Claudin 5 (CLDN5) | WB; IHC; ICC; IP. |
MAF295Hu21 | Monoclonal Antibody to Claudin 5 (CLDN5) | WB; IHC; ICC; IP. |
SEF295Hu | ELISA Kit for Claudin 5 (CLDN5) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEF295Hu | Mini Samples ELISA Kit for Claudin 5 (CLDN5) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMF295Hu | Multiplex Assay Kit for Claudin 5 (CLDN5) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |