Mini Samples ELISA Kit for Peptide YY (PYY)

PYY1; Peptide tyrosine tyrosine

Specificity

This assay has high sensitivity and excellent specificity for detection of Mini Samples Peptide YY (PYY).
No significant cross-reactivity or interference between Mini Samples Peptide YY (PYY) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Mini Samples Peptide YY (PYY) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Peptide YY (PYY) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-101 97
EDTA plasma(n=5) 86-104 90
heparin plasma(n=5) 92-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Peptide YY (PYY) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Peptide YY (PYY) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Peptide YY (PYY) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 99-105% 86-99% 83-105% 89-97%
EDTA plasma(n=5) 79-98% 86-94% 81-95% 83-96%
heparin plasma(n=5) 91-105% 91-105% 78-95% 80-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×60µL Assay Diluent A 1×6mL
Detection Reagent B 1×60µL Assay Diluent B 1×6mL
TMB Substrate 1×9mL Stop Solution 1×3mL
Wash Buffer (30 × concentrate) 1×10mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well.
    And then add 25μL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 50µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 50µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 25µL Stop Solution. Read at 450 nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
International Journal of Sport Studies The Effects of Concurrent Resistance and Endurance Exercise on Hunger Feelings and PYY in Obese Men Com:Source
Annals of Applied Sport Science Effect of an Acute Incremental Exercise on Plasma Peptide YY, Neuropeptide Y and IGF-1 Concentrations in Young Athletes Aassjournal:Source
Biomedical Reports Calprotectin in serum and zonulin in serum and feces are elevated after introduction of a diet with lower carbohydrate content and higher fiber, fat and protein contents. pubmed:28413639
Acta Diabetologica Effect of lifestyle improvement program on the biomarkersof adiposity, inflammation and gut hormones in overweight/obese Asian Indians with prediabetes pubmed:28620678
Biomedical Reports Calprotectin in serum and zonulin in serum and feces are elevated after introduction of a diet with lower carbohydrate content and higher fiber, fat and protein contents 10.3892/br.2017.865
Journal of Diabetes & Metabolism High Fiber Fat and Protein Contents Lead to Increased Satiety Reduced Sweet Cravings and Decreased Gastrointestinal Symptoms Independently of Anthropometric Hormonal and Metabolic Factors 10.4172/2155-6156.1000733 
Frontiers in Physiology Ileal Transposition Surgery Decreases Fat Mass and Improves Glucose Metabolism in Diabetic GK Rats: Possible Involvement of FGF21 Pubmed:29593555
Food and Nutrition Research Alignments of endocrine, anthropometric, and metabolic parameters in type 2 diabetes after intervention with an Okinawa-based Nordic diet Pubmed:29599686
The Journal of Nutrition Grape Seed Proanthocyanidin Affects Lipid Metabolism via Changing Gut Microflora and Enhancing Propionate Production in Weaned Pigs Pubmed: 31175811
The Journal of Nutritional Biochemistry Bile acid receptor TGR5 is critically involved in preference for dietary lipids and obesity Pubmed: 31812910
Arch Toxicol Serotonin involvement in okadaic acid-induced diarrhoea in vivo 34148100
foods Appetite and Satiety Effects of the Acute and Regular Consumption of Green Coffee Phenols and Green Coffee Phenol/Oat β-Glucan Nutraceuticals in Subjects with … 34828792
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPB067Ra01 Recombinant Peptide YY (PYY) Positive Control; Immunogen; SDS-PAGE; WB.
CPB067Ra21 OVA Conjugated Peptide YY (PYY) Immunogen; SDS-PAGE; WB.
PAB067Ra01 Polyclonal Antibody to Peptide YY (PYY) WB; IHC; ICC; IP.
MAB067Ra21 Monoclonal Antibody to Peptide YY (PYY) WB; IHC; ICC; IP.
CEB067Ra ELISA Kit for Peptide YY (PYY) Enzyme-linked immunosorbent assay for Antigen Detection.
MEB067Ra Mini Samples ELISA Kit for Peptide YY (PYY) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB067Ra Multiplex Assay Kit for Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB067Ra11 ELISA Kit DIY Materials for Peptide YY (PYY) Main materials for "Do It (ELISA Kit) Yourself".