Mini Samples ELISA Kit for Monocyte Chemotactic Protein 2 (MCP2)

CCL8; CCL-8; SCYA8; MCP-2; HC14; Chemokine C-C-Motif Ligand 8; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 8; Monocyte Chemoattractant Protein 2

Specificity

This assay has high sensitivity and excellent specificity for detection of Mini Samples Monocyte Chemotactic Protein 2 (MCP2).
No significant cross-reactivity or interference between Mini Samples Monocyte Chemotactic Protein 2 (MCP2) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Mini Samples Monocyte Chemotactic Protein 2 (MCP2) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Monocyte Chemotactic Protein 2 (MCP2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-92 89
EDTA plasma(n=5) 83-97 86
heparin plasma(n=5) 80-90 80

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Monocyte Chemotactic Protein 2 (MCP2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Monocyte Chemotactic Protein 2 (MCP2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Monocyte Chemotactic Protein 2 (MCP2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 95-104% 82-96% 97-105%
EDTA plasma(n=5) 99-105% 95-102% 97-105% 80-91%
heparin plasma(n=5) 91-98% 90-97% 87-102% 86-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×60µL Assay Diluent A 1×6mL
Detection Reagent B 1×60µL Assay Diluent B 1×6mL
TMB Substrate 1×4.5mL Stop Solution 1×3mL
Wash Buffer (30 × concentrate) 1×10mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA088Mu01 Recombinant Monocyte Chemotactic Protein 2 (MCP2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA088Mu01 Polyclonal Antibody to Monocyte Chemotactic Protein 2 (MCP2) WB; IHC; ICC; IP.
MEA088Mu Mini Samples ELISA Kit for Monocyte Chemotactic Protein 2 (MCP2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA088Mu Multiplex Assay Kit for Monocyte Chemotactic Protein 2 (MCP2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.