Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Mini Samples ELISA Kit for Endothelial protein C receptor (EPCR)
CD201; PROCR; CCCA ;CCD41; BA42O4.2; EPCR; Endothelial Protein C Receptor; Cell Cycle, Centrosome-Associated Protein; Activated Protein C Receptor
- Product No.MEA022Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range1.56-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.62ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 575
For more details, please contact local distributors! US$ 821 US$ 3695 US$ 6979 US$ 57470
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples Endothelial protein C receptor (EPCR).
No significant cross-reactivity or interference between Mini Samples Endothelial protein C receptor (EPCR) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Mini Samples Endothelial protein C receptor (EPCR) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Endothelial protein C receptor (EPCR) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 98-105 | 102 |
EDTA plasma(n=5) | 82-101 | 89 |
heparin plasma(n=5) | 88-103 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Endothelial protein C receptor (EPCR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Endothelial protein C receptor (EPCR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Endothelial protein C receptor (EPCR) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 87-104% | 80-96% | 91-105% | 89-102% |
EDTA plasma(n=5) | 82-89% | 96-104% | 84-98% | 83-104% |
heparin plasma(n=5) | 92-101% | 87-105% | 87-101% | 89-97% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×60µL | Assay Diluent A | 1×6mL |
Detection Reagent B | 1×60µL | Assay Diluent B | 1×6mL |
TMB Substrate | 1×4.5mL | Stop Solution | 1×3mL |
Wash Buffer (30 × concentrate) | 1×10mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
ВЕСТНИК НОВЫХ МЕДИЦИНСКИХ ТЕХНОЛОГИЙ | СОВЕРШЕНСТВОВАНИЕ ЛЕЧЕБНО-ДИАГНОСТИЧЕСКИХ МЕРОПРИЯТИЙ ПРИ ГРИППЕ ВО ВРЕМЯ БЕРЕМЕННОСТИ Bulletin: E2015-1 |
Experimental and Therapeutic Medicine | Unfractionated heparin protects the protein C system against lipopolysaccharide‑induced damage in vivo and in vitro 10.3892/etm.2017.5236 |
Biomed Pharmacother | Effects and mechanisms of PSS-loaded nanoparticles on coronary microcirculation dysfunction in streptozotocin-induced diabetic cardiomyopathy rats Pubmed: 31715373 |
BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE | Effect of Nitinol on Metabolic and Coagulation Activity of Endothelial Cells Culture 34542754 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA022Ra01 | Recombinant Endothelial protein C receptor (EPCR) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA022Ra01 | Polyclonal Antibody to Endothelial protein C receptor (EPCR) | WB; IHC; ICC; IP. |
LAA022Ra71 | Biotin-Linked Polyclonal Antibody to Endothelial protein C receptor (EPCR) | WB; IHC; ICC. |
MAA022Ra21 | Monoclonal Antibody to Endothelial protein C receptor (EPCR) | WB; IHC; ICC; IP. |
MEA022Ra | Mini Samples ELISA Kit for Endothelial protein C receptor (EPCR) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEA022Ra | ELISA Kit for Endothelial protein C receptor (EPCR) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA022Ra | Multiplex Assay Kit for Endothelial protein C receptor (EPCR) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |