Multiplex Assay Kit for Glutathione S Transferase (GST) ,etc. by FLIA (Flow Luminescence Immunoassay)

GST-Tag

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Glutathione S Transferase (GST).
No significant cross-reactivity or interference between Glutathione S Transferase (GST) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Glutathione S Transferase (GST) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutathione S Transferase (GST) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-105 102
EDTA plasma(n=5) 92-101 95
heparin plasma(n=5) 89-99 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutathione S Transferase (GST) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutathione S Transferase (GST) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutathione S Transferase (GST) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-95% 86-101% 90-102% 92-101%
EDTA plasma(n=5) 96-103% 85-99% 88-99% 80-103%
heparin plasma(n=5) 91-102% 94-102% 79-102% 90-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GST) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Free radical research Circulating cell-free DNA of methylated insulin-like growth factor-binding protein 7 predicts a poor prognosis in hepatitis B virus-associated hepatocellular carcinoma … Pubmed:29463155
Journal of Molecular and Cellular Cardiology SESN2 protects against doxorubicin-induced cardiomyopathy via rescuing mitophagy and improving mitochondrial function Pubmed: 31199952
Journal of Cell Biology Insulin activates intracellular transport of lipid droplets to release triglycerides from the liver Pubmed: 31604801
Biochemical and Biophysical Research Communications Kinesin associated protein, DmKAP, binding harnesses the C-terminal ends of the Drosophila kinesin-2 stalk heterodimer Pubmed: 31784087
International Journal of Nature and Life Sciences The Role of Glutathione S-Transferases in Pleomorphic Adenomas of the Salivary Glands
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
RPX158Ge01 Recombinant Glutathione S Transferase (GST) Positive Control; Immunogen; SDS-PAGE; WB.
RPX158Ge02 Recombinant Glutathione S Transferase (GST) Positive Control; Immunogen; SDS-PAGE; WB.
TAX158Ge01 Anti-Glutathione S Transferase (GST) Tag Polyclonal Antibody WB; Dot Blot; IP.
MAX158Ge22 Monoclonal Antibody to Glutathione S Transferase (GST) WB
MAX158Ge21 Monoclonal Antibody to Glutathione S Transferase (GST) WB; IHC; ICC; IP.
TAX158Ge22 Anti-Glutathione S Transferase (GST) Tag Monoclonal Antibody WB; Dot Blot; IP.
SEX158Ge ELISA Kit for Glutathione S Transferase (GST) Enzyme-linked immunosorbent assay for Antigen Detection.
LMX158Ge Multiplex Assay Kit for Glutathione S Transferase (GST) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.