Multiplex Assay Kit for T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay)

TBLYM; TBET; T-box transcription factor TBX21; T-cell-specific T-box transcription factor T-bet

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-95 91
EDTA plasma(n=5) 94-102 99
heparin plasma(n=5) 94-101 97
sodium citrate plasma(n=5) 83-97 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-99% 83-102% 82-90% 88-96%
EDTA plasma(n=5) 78-99% 93-101% 83-99% 89-98%
heparin plasma(n=5) 87-94% 78-89% 81-97% 98-105%
sodium citrate plasma(n=5) 88-102% 87-95% 90-102% 80-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TBX21) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biomed Research International Effects of 2, 3, 7, 8-Tetrachlorodibenzo-p-dioxin on T Cell Differentiation in Primary Biliary Cholangitis Pubmed: 32908870
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPP605Hu01 Recombinant T-Box Protein 21 (TBX21) Positive Control; Immunogen; SDS-PAGE; WB.
PAP605Hu01 Polyclonal Antibody to T-Box Protein 21 (TBX21) WB; IHC; ICC; IP.
MAP605Hu21 Monoclonal Antibody to T-Box Protein 21 (TBX21) WB; IHC; ICC; IP.
SEP605Hu ELISA Kit for T-Box Protein 21 (TBX21) Enzyme-linked immunosorbent assay for Antigen Detection.
LMP605Hu Multiplex Assay Kit for T-Box Protein 21 (TBX21) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.