Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Taurocholic Acid (TCA) ,etc. by FLIA (Flow Luminescence Immunoassay)
Cholaic Acid; Cholyltaurine; Acidum Cholatauricum
(Note: Up to 8-plex in one testing reaction)
- Product No.LMO267Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample TypeBiological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range0.29-300ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.097 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 561
US$ 582
US$ 614
US$ 658
US$ 701
US$ 765
US$ 862
US$ 1078
Add to Price Calculator
Result
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Taurocholic Acid (TCA).
No significant cross-reactivity or interference between Taurocholic Acid (TCA) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Taurocholic Acid (TCA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Taurocholic Acid (TCA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:TCA) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
| CEO267Ge | ELISA Kit for Taurocholic Acid (TCA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CMO267Ge | Multiplex Assay Kit for Taurocholic Acid (TCA) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMO267Ge | Multiplex Assay Kit for Taurocholic Acid (TCA) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |

