Multiplex Assay Kit for Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay)
MAP1ALC3; MAP1BLC3; LC3; LC3A; ATG8E; Autophagy-related ubiquitin-like modifier LC3 A; MAP1 light chain 3-like protein 1
(Note: Up to 8-plex in one testing reaction)
- Product No.LML701Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeTissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.02-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.007 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 522
US$ 542
US$ 572
US$ 612
US$ 652
US$ 712
US$ 802
Result
For more details, please contact local distributors! US$ 1003 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-102 | 99 |
EDTA plasma(n=5) | 79-88 | 80 |
heparin plasma(n=5) | 93-105 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 94-101% | 92-101% | 97-104% | 80-102% |
EDTA plasma(n=5) | 80-97% | 85-101% | 80-103% | 78-103% |
heparin plasma(n=5) | 93-104% | 85-104% | 91-99% | 92-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:MAP1LC3a) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
BRIEFINGS IN BIOINFORMATICS | Lysosome activation in peripheral blood mononuclear cells and prognostic significance of circulating LC3B in COVID-19 33620066 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPL701Ra01 | Recombinant Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAL701Ra01 | Polyclonal Antibody to Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) | WB; IHC; ICC; IP. |
MAL701Ra21 | Monoclonal Antibody to Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) | WB; IHC; ICC; IP. |
SEL701Ra | ELISA Kit for Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LML701Ra | Multiplex Assay Kit for Microtubule Associated Protein 1 Light Chain 3 Alpha (MAP1LC3a) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |