Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay)
Ethinyl Estradiol ; Ethynyl Estradiol; Ethinyl Oestradiol
(Note: Up to 8-plex in one testing reaction)
- Product No.LMK510Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range1.95-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.65 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 509
US$ 529
US$ 558
US$ 597
US$ 636
US$ 695
US$ 783
Result
For more details, please contact local distributors! US$ 979 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 84-93 | 90 |
EDTA plasma(n=5) | 81-94 | 85 |
heparin plasma(n=5) | 79-101 | 84 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-104% | 78-88% | 95-102% | 85-94% |
EDTA plasma(n=5) | 78-101% | 89-103% | 96-104% | 94-105% |
heparin plasma(n=5) | 85-103% | 99-105% | 79-105% | 90-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:EE) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Talanta | Electrochemical immunosensor for ethinylestradiol using diazonium salt grafting onto silver nanoparticles-silica–graphene oxide hybrids PubMed: 26592615 |
African Journal of Environmental Science and Technology | Pollution by endocrine disrupting estrogens in aquatic ecosystems in Morogoro urban and peri-urban areas in Tanzania 150659 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPK510Ge11 | BSA Conjugated Ethinylestradiol (EE) | Immunogen; SDS-PAGE; WB. |
CPK510Ge21 | OVA Conjugated Ethinylestradiol (EE) | Immunogen; SDS-PAGE; WB. |
PAK510Ge01 | Polyclonal Antibody to Ethinylestradiol (EE) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAK510Ge22 | Monoclonal Antibody to Ethinylestradiol (EE) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAK510Ge23 | Monoclonal Antibody to Ethinylestradiol (EE) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAK510Ge21 | Monoclonal Antibody to Ethinylestradiol (EE) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
CEK510Ge | ELISA Kit for Ethinylestradiol (EE) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMK510Ge | Multiplex Assay Kit for Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSK510Ge11 | ELISA Kit DIY Materials for Ethinylestradiol (EE) | Main materials for "Do It (ELISA Kit) Yourself". |