Multiplex Assay Kit for Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay)

YWHAS; HME1; 14-3-3 Protein Sigma; Epithelial cell marker protein 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-101 88
EDTA plasma(n=5) 78-99 82
heparin plasma(n=5) 86-104 93
sodium citrate plasma(n=5) 83-105 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 85-97% 84-95% 96-104%
EDTA plasma(n=5) 91-99% 82-101% 80-101% 89-97%
heparin plasma(n=5) 80-91% 88-102% 80-90% 87-101%
sodium citrate plasma(n=5) 80-88% 79-97% 80-94% 96-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:SFN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Molecular & Cellular Proteomics A Protein Epitope Signature Tag (PrEST) Library Allows SILAC-based Absolute Quantification and Multiplexed Determination of Protein Copy Numbers in Cell Lines Mcponline: 009613
GEBURTSHILFE UND FRAUENHEILKUNDE Prediction of Spontaneous Preterm Birth in At-risk Women Using Thrombospondin 1 from Cervicovaginal Fluid: A Prospective Observational Study 34531612
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPH179Hu01 Recombinant Stratifin (SFN) Positive Control; Immunogen; SDS-PAGE; WB.
PAH179Hu01 Polyclonal Antibody to Stratifin (SFN) WB
FAH179Hu01 Anti-Stratifin (SFN) Polyclonal Antibody Flow cytometry.
LAH179Hu71 Biotin-Linked Polyclonal Antibody to Stratifin (SFN) WB; IHC; ICC.
LAH179Hu81 FITC-Linked Polyclonal Antibody to Stratifin (SFN) WB; IHC; ICC; IF.
MAH179Hu21 Monoclonal Antibody to Stratifin (SFN) WB; IHC; ICC; IP.
SEH179Hu ELISA Kit for Stratifin (SFN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMH179Hu Multiplex Assay Kit for Stratifin (SFN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.