Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay)
PtdIns
(Note: Up to 8-plex in one testing reaction)
- Product No.LMG853Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range9.77-10000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 3.257 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 505
US$ 525
US$ 554
US$ 593
US$ 632
US$ 690
US$ 778
Result
For more details, please contact local distributors! US$ 972 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 94-102 | 99 |
EDTA plasma(n=5) | 93-101 | 97 |
heparin plasma(n=5) | 97-105 | 102 |
sodium citrate plasma(n=5) | 80-103 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 87-95% | 84-99% | 86-97% | 84-94% |
EDTA plasma(n=5) | 80-98% | 88-95% | 85-97% | 95-105% |
heparin plasma(n=5) | 79-95% | 97-105% | 98-105% | 90-97% |
sodium citrate plasma(n=5) | 79-101% | 78-101% | 92-99% | 78-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PI) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPG853Ge11 | BSA Conjugated Phosphatidylinositol (PI) | Immunogen; SDS-PAGE; WB. |
CPG853Ge21 | OVA Conjugated Phosphatidylinositol (PI) | Immunogen; SDS-PAGE; WB. |
PAG853Ge01 | Polyclonal Antibody to Phosphatidylinositol (PI) | WB; IHC; ICC; IP. |
CEG853Ge | ELISA Kit for Phosphatidylinositol (PI) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMG853Ge | Multiplex Assay Kit for Phosphatidylinositol (PI) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSG853Ge11 | ELISA Kit DIY Materials for Phosphatidylinositol (PI) | Main materials for "Do It (ELISA Kit) Yourself". |