≡

Multiplex Assay Kit for Interferon Alpha/Beta Receptor 2 (IFNa/bR2) ,etc. by FLIA (Flow Luminescence Immunoassay)

IFNAR2; IFN-alpha-REC; IFN-R; IFNABR; IFNARB; Interferon(Alpha,Beta And Omega)Receptor Beta Chain; Interferon alpha binding protein; Type I interferon receptor 2

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Interferon Alpha/Beta Receptor 2 (IFNa/bR2).
No significant cross-reactivity or interference between Interferon Alpha/Beta Receptor 2 (IFNa/bR2) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Interferon Alpha/Beta Receptor 2 (IFNa/bR2) and the recovery rates were calculated by comparing the measured value to the expected amount of Interferon Alpha/Beta Receptor 2 (IFNa/bR2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-99 93
EDTA plasma(n=5) 78-104 101
heparin plasma(n=5) 82-91 86
sodium citrate plasma(n=5) 79-98 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interferon Alpha/Beta Receptor 2 (IFNa/bR2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interferon Alpha/Beta Receptor 2 (IFNa/bR2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interferon Alpha/Beta Receptor 2 (IFNa/bR2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-104% 81-104% 78-91% 92-101%
EDTA plasma(n=5) 91-99% 89-104% 81-94% 79-90%
heparin plasma(n=5) 89-102% 90-99% 81-94% 88-95%
sodium citrate plasma(n=5) 86-98% 94-105% 94-102% 85-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:IFNa/bR2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Jundishapur Journal of Microbiology. Higher Serum Levels of Type I Interferon Receptor in Adults with Chronic Hepatitis B Leading to Hepatitis B Surface Antigen Clearance 41319
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPE171Hu01 Recombinant Interferon Alpha/Beta Receptor 2 (IFNa/bR2) Positive Control; Immunogen; SDS-PAGE; WB.
PAE171Hu01 Polyclonal Antibody to Interferon Alpha/Beta Receptor 2 (IFNa/bR2) WB; IHC; ICC/IF
MAE171Hu21 Monoclonal Antibody to Interferon Alpha/Beta Receptor 2 (IFNa/bR2) WB; IHC; ICC; IP.
SEE171Hu ELISA Kit for Interferon Alpha/Beta Receptor 2 (IFNa/bR2) Enzyme-linked immunosorbent assay for Antigen Detection.
CME171Hu Multiplex Assay Kit for Interferon Alpha/Beta Receptor 2 (IFNa/bR2) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LME171Hu Multiplex Assay Kit for Interferon Alpha/Beta Receptor 2 (IFNa/bR2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.