Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay)
DEFB103; DEFB3; HBD-3; HBD3; HBP-3; HBP3; Beta-defensin 3; Defensin-like protein
(Note: Up to 8-plex in one testing reaction)
- Product No.LME132Bo
- Organism SpeciesBos taurus; Bovine (Cattle) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids.
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range1.95-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.65 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 524
US$ 544
US$ 575
US$ 615
US$ 655
US$ 716
US$ 806
Result
For more details, please contact local distributors! US$ 1008 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 83-90 | 86 |
EDTA plasma(n=5) | 79-97 | 88 |
heparin plasma(n=5) | 80-92 | 83 |
sodium citrate plasma(n=5) | 91-105 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-98% | 91-101% | 96-105% | 78-95% |
EDTA plasma(n=5) | 97-105% | 94-102% | 88-103% | 97-105% |
heparin plasma(n=5) | 87-101% | 88-101% | 85-92% | 85-94% |
sodium citrate plasma(n=5) | 79-96% | 90-101% | 87-101% | 83-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:DEFb103A) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Plos Pathogens | HIF-1α Is Essential for Effective PMN Bacterial Killing, Antimicrobial Peptide Production and Apoptosis in?Pseudomonas aeruginosa?Keratitis PubMed: PMC3715414 |
Scientific Reports | Measurements of AMPs in stratum corneum of atopic dermatitis and healthy skin–tape stripping technique Pubmed:29374283 |
PeerJ | Antibacterial activity of human defensins against Staphylococcus aureus and Escherichia coli 33304659 |
Animals | Fat Encapsulation Reduces Diarrhea in Piglets Partially by Repairing the Intestinal Barrier and Improving Fatty Acid Transport 33375218 |
Sci Rep | Human beta defensin levels and vaginal microbiome composition in post-menopausal women diagnosed with lichen sclerosus 34362937 |
Catalog No. | Related products for research use of Bos taurus; Bovine (Cattle) Organism species | Applications (RESEARCH USE ONLY!) |
RPE132Bo01 | Recombinant Defensin Beta 103A (DEFb103A) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAE132Bo01 | Polyclonal Antibody to Defensin Beta 103A (DEFb103A) | WB; IHC; ICC; IP. |
MAE132Bo21 | Monoclonal Antibody to Defensin Beta 103A (DEFb103A) | WB; IHC; ICC; IP. |
SEE132Bo | ELISA Kit for Defensin Beta 103A (DEFb103A) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LME132Bo | Multiplex Assay Kit for Defensin Beta 103A (DEFb103A) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |