Multiplex Assay Kit for Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay)

SYL; INSSA1; Insulin Synthesis Associated 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-96 88
EDTA plasma(n=5) 78-96 85
heparin plasma(n=5) 80-94 88
sodium citrate plasma(n=5) 94-101 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-97% 78-91% 83-94% 90-103%
EDTA plasma(n=5) 88-102% 79-101% 88-101% 80-88%
heparin plasma(n=5) 79-90% 85-99% 78-93% 90-98%
sodium citrate plasma(n=5) 78-104% 90-99% 82-94% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:SYCN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Molecular & Cellular Proteomics Integrated Proteomic Profiling of Cell Line Conditioned Media and Pancreatic Juice for the Identification of Pancreatic Cancer Biomarkers PubMed: PMC3205865
BMC Cancer. Validation of four candidate pancreatic cancer serological biomarkers that improve the performance of CA19.10 Pubmed: 24007603
Clinical Cancer Research Validation of Biomarkers That Complement CA19.9 in Detecting Early Pancreatic Cancer Pubmed:25239611
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD879Hu01 Recombinant Syncollin (SYCN) Positive Control; Immunogen; SDS-PAGE; WB.
PAD879Hu01 Polyclonal Antibody to Syncollin (SYCN) WB; IHC; ICC; IP.
MAD879Hu21 Monoclonal Antibody to Syncollin (SYCN) WB; IHC; ICC; IP.
SED879Hu ELISA Kit for Syncollin (SYCN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD879Hu Multiplex Assay Kit for Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.