Multiplex Assay Kit for Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay)

AGT2; Beta-Alanine-Pyruvate Aminotransferase; (R)-3-amino-2-methylpropionate--pyruvate transaminase

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 94-102 98
heparin plasma(n=5) 92-105 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-99% 94-101% 82-94% 96-105%
EDTA plasma(n=5) 89-98% 86-101% 84-92% 83-90%
heparin plasma(n=5) 80-104% 78-88% 92-101% 78-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AGXT2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD855Hu01 Recombinant Alanine Glyoxylate Aminotransferase 2 (AGXT2) Positive Control; Immunogen; SDS-PAGE; WB.
PAD855Hu01 Polyclonal Antibody to Alanine Glyoxylate Aminotransferase 2 (AGXT2) WB; IHC; ICC; IP.
SED855Hu ELISA Kit for Alanine Glyoxylate Aminotransferase 2 (AGXT2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD855Hu Multiplex Assay Kit for Alanine Glyoxylate Aminotransferase 2 (AGXT2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.