Multiplex Assay Kit for Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay)

CG-B; CGB3; hCGB; HCG; CGb5; CGb7; CGb8; Choriogonadotropin subunit beta

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-105 101
EDTA plasma(n=5) 91-105 94
heparin plasma(n=5) 86-101 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 89-101% 97-105% 81-90%
EDTA plasma(n=5) 80-97% 90-97% 90-98% 79-91%
heparin plasma(n=5) 93-101% 90-98% 80-93% 80-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CGb) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
临床输血与检验 联合检测血清血管内皮生长因子和β-HCG对早期异位妊娠的诊断意义 1671-2587
Biomarkers Regulation of circulating chromogranin B levels in heart failure Pubmed:29098879
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD215Hu01 Recombinant Chorionic Gonadotropin Beta Polypeptide (CGb) Positive Control; Immunogen; SDS-PAGE; WB.
PAD215Hu01 Polyclonal Antibody to Chorionic Gonadotropin Beta Polypeptide (CGb) WB; IHC; ICC; IP.
MAD215Hu21 Monoclonal Antibody to Chorionic Gonadotropin Beta Polypeptide (CGb) WB; IHC; ICC; IP.
MAD215Hu22 Monoclonal Antibody to Chorionic Gonadotropin Beta Polypeptide (CGb) WB; IHC; ICC; IP.
MAD215Hu24 Monoclonal Antibody to Chorionic Gonadotropin Beta Polypeptide (CGb) WB; IHC; ICC; IP.
MAD215Hu23 Monoclonal Antibody to Chorionic Gonadotropin Beta Polypeptide (CGb) WB; IHC; ICC; IP.
SED215Hu ELISA Kit for Chorionic Gonadotropin Beta Polypeptide (CGb) Enzyme-linked immunosorbent assay for Antigen Detection.
CED215Hu ELISA Kit for Chorionic Gonadotropin Beta Polypeptide (CGb) Enzyme-linked immunosorbent assay for Antigen Detection.
AED215Hu ELISA Kit for Anti-Chorionic Gonadotropin Beta Polypeptide Antibody (Anti-CGb) Enzyme-linked immunosorbent assay for Antibody Detection.
LMD215Hu Multiplex Assay Kit for Chorionic Gonadotropin Beta Polypeptide (CGb) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSD215Hu01 ELISA Kit DIY Materials for Chorionic Gonadotropin Beta Polypeptide (CGb) Main materials for "Do It (ELISA Kit) Yourself".