Multiplex Assay Kit for Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay)

CRF-R; CRF1; CRFR1; CRH-R1h; CRHR; CRHR1f; Corticotropin-releasing factor receptor 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 97
EDTA plasma(n=5) 88-98 92
heparin plasma(n=5) 82-96 90
sodium citrate plasma(n=5) 79-96 82

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-97% 93-101% 80-101% 89-104%
EDTA plasma(n=5) 87-101% 83-103% 94-101% 84-93%
heparin plasma(n=5) 87-102% 98-105% 78-98% 99-105%
sodium citrate plasma(n=5) 89-99% 89-103% 91-98% 82-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CRHR1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Neuroscience & Medicine Involvement of CRH Receptors in the Neuroprotective Action of R-Apomorphine in the Striatal 6-OHDA Rat Model Scirp: Source
Placenta Human placentophagy: Effects of dehydration and steaming on hormones, metals and bacteria in placental tissue Pubmed:29941176
Journal of tranditional chinese medical sciences Ganjiang granule regulates cecal microflora and serum biochemical components in a rat model of constipation-predominant irritable bowel syndrome
International Journal of?Nanomedicine Water-Soluble Carbon Dots in Cigarette Mainstream Smoke: Their Properties and the Behavioural, Neuroendocrinological, and Neurotransmitter Changes They ¡­ 33762821
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPC935Ra01 Recombinant Corticotropin Releasing Hormone Receptor 1 (CRHR1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC935Ra01 Polyclonal Antibody to Corticotropin Releasing Hormone Receptor 1 (CRHR1) WB; IHC; ICC; IP.
MAC935Ra21 Monoclonal Antibody to Corticotropin Releasing Hormone Receptor 1 (CRHR1) WB; IHC; ICC; IP.
SEC935Ra ELISA Kit for Corticotropin Releasing Hormone Receptor 1 (CRHR1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC935Ra Multiplex Assay Kit for Corticotropin Releasing Hormone Receptor 1 (CRHR1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.