Multiplex Assay Kit for Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay)

SAP1; GLBA; CSAct; Dispersin; Pro-Saposin; Proactivator polypeptide; Glucosylceramidase activator; Sulfatide/GM1 activator; Cerebroside sulfate activator; Sphingolipid Activator 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-98 93
EDTA plasma(n=5) 78-89 82
heparin plasma(n=5) 81-91 85

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 87-99% 79-96% 80-91%
EDTA plasma(n=5) 96-104% 87-94% 85-101% 86-94%
heparin plasma(n=5) 78-103% 78-105% 90-97% 89-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PSAP) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Translational Research in Oral Oncology Testican 1 (SPOCK1) and protein tyrosine phosphatase, receptor type S (PTPRS) show significant increase in saliva of tobacco users with oral cancer Doi: 10.1177/2057178X18800534
PeerJ Prosaposin in seminal plasma on the day of oocyte retrieval is associated with normal fertilization and embryo development in in vitro fertilization cycles Pubmed: 31844578
CANCER GENOMICS & PROTEOMICS Putative Biomarkers for Malignant Pleural Mesothelioma Suggested by Proteomic Analysis of Cell Secretome Pubmed: 32345664
Frontiers in Microbiology Surface Protein Dispersin of Enteroaggregative Escherichia coli Binds Plasminogen That Is Converted Into Active Plasmin Pubmed: 32625178
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC756Hu01 Recombinant Prosaposin (PSAP) Positive Control; Immunogen; SDS-PAGE; WB.
PAC756Hu01 Polyclonal Antibody to Prosaposin (PSAP) WB,IHC,ICC/IF
MAC756Hu22 Monoclonal Antibody to Prosaposin (PSAP) WB; IHC; ICC; IP.
MAC756Hu21 Monoclonal Antibody to Prosaposin (PSAP) WB; IHC; ICC; IP.
MAC756Hu23 Monoclonal Antibody to Prosaposin (PSAP) WB; IHC; ICC; IP.
MAC756Hu24 Monoclonal Antibody to Prosaposin (PSAP) WB; IHC; ICC; IP.
SEC756Hu ELISA Kit for Prosaposin (PSAP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC756Hu Multiplex Assay Kit for Prosaposin (PSAP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSC756Hu01 ELISA Kit DIY Materials for Prosaposin (PSAP) Main materials for "Do It (ELISA Kit) Yourself".