Multiplex Assay Kit for Histidine Rich Glycoprotein (HRG) ,etc. by FLIA (Flow Luminescence Immunoassay)
HPRG; HRGP; Histidine-Proline Rich Glycoprotein; Thrombophilia Due To Elevated HRG
(Note: Up to 8-plex in one testing reaction)
- Product No.LMC534Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.03-30ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.01 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 437
US$ 454
US$ 479
US$ 512
US$ 546
US$ 596
US$ 672
Result
For more details, please contact local distributors! US$ 840 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Histidine Rich Glycoprotein (HRG) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Histidine Rich Glycoprotein (HRG) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Histidine Rich Glycoprotein (HRG) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Histidine Rich Glycoprotein (HRG) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-95 | 82 |
EDTA plasma(n=5) | 85-96 | 89 |
heparin plasma(n=5) | 79-92 | 85 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Histidine Rich Glycoprotein (HRG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Histidine Rich Glycoprotein (HRG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Histidine Rich Glycoprotein (HRG) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-95% | 98-105% | 85-95% | 85-101% |
EDTA plasma(n=5) | 80-105% | 95-104% | 80-90% | 96-105% |
heparin plasma(n=5) | 80-98% | 84-98% | 99-105% | 90-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:HRG) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
J. Proteome Res. | Identification and Confirmation of Differentially Expressed Fucosylated Glycoproteins in the Serum of Ovarian Cancer Patients Using a Lectin Array and LC–MS/MS ACS: pr300330z |
Medical Oncology | Evaluation of histidine-rich glycoprotein tissue RNA and serum protein as novel markers for breast cancer Springer: Source |
Int J Cancer | The nuclear bile acid receptor FXR controls the liver derived tumor suppressor histidine‐rich glycoprotein PubMed: 25363753 |
Nucleic Acid Therapeutics | Pharmacokinetic and Pharmacodynamic Investigations of ION-353382, a Model Antisense Oligonucleotide: Using Alpha-2-Macroglobulin and Murinoglobulin Double-Knockout Mice Pubmed:27031383 |
United States Patent Application | Compositions and Methods for Diagnosing Lung Cancer y2016:0077095.html |
Hypertension Research | Combination of serum histidine-rich glycoprotein and uterine artery Doppler to predict preeclampsia Pubmed:29416108 |
journal of histochemistry & cytochemistry | Ultrastructural Localization of Histidine-rich Glycoprotein in Skeletal Muscle Fibers: Colocalization With AMP Deaminase Pubmed: 31880188 |
DOKLADY BIOCHEMISTRY AND BIOPHYSICS | Personalized Approach to Determination of Histidine-Rich Glycoprotein and E-Cadherin in Supernatants of Immunocompetent Blood Cells and Breast Biopsy … Pubmed: 32342301 |