Multiplex Assay Kit for Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay)
AT3; ATIII; SERPINC1; Anti-Thrombin Antibodies; Serpin Peptidase Inhibitor Clade C Member 1; Coding Sequence Signal Peptide Antithrombin Part 1
(Note: Up to 8-plex in one testing reaction)
- Product No.LMC313Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypePlasma
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 474
US$ 492
US$ 520
US$ 556
US$ 593
US$ 648
US$ 730
Result
For more details, please contact local distributors! US$ 912 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-105 | 101 |
EDTA plasma(n=5) | 98-105 | 101 |
heparin plasma(n=5) | 78-91 | 87 |
sodium citrate plasma(n=5) | 96-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-90% | 91-99% | 91-104% | 94-101% |
EDTA plasma(n=5) | 87-102% | 97-104% | 78-101% | 84-91% |
heparin plasma(n=5) | 82-98% | 79-91% | 82-96% | 80-93% |
sodium citrate plasma(n=5) | 84-91% | 91-105% | 78-94% | 84-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:AT) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Thromb Res | Thalidomide and multiple myeloma serum synergistically induce a hemostatic imbalance in endothelial cells in vitro PubMed: 25840743 |
Neurotherapeutics | iTRAQ-Based Quantitative Proteomics Reveals the New Evidence Base for Traumatic Brain Injury Treated with Targeted Temperature Management pubmed:29247448 |
Journal of Clinical and Aesthetic Dermatology | Detection of Angiotensin II and AT1 Receptor Concentrations in Keloid and Hypertrophic Scar. |
博士论文 | An Agile Approach to Novel Recombinant Antithrombin Production for use in Biologics Development |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPC313Ra01 | Recombinant Antithrombin (AT) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPC313Ra02 | Recombinant Antithrombin (AT) | Positive Control; Immunogen; SDS-PAGE; WB. |
APC313Ra02 | Active Antithrombin (AT) | Cell culture; Activity Assays. |
PAC313Ra02 | Polyclonal Antibody to Antithrombin (AT) | WB; IHC; ICC; IP. |
PAC313Ra01 | Polyclonal Antibody to Antithrombin (AT) | WB; IHC; ICC; IP. |
MAC313Ra21 | Monoclonal Antibody to Antithrombin (AT) | WB; IHC; ICC; IP. |
SEC313Ra | ELISA Kit for Antithrombin (AT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMC313Ra | Multiplex Assay Kit for Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSC313Ra01 | ELISA Kit DIY Materials for Antithrombin (AT) | Main materials for "Do It (ELISA Kit) Yourself". |