Multiplex Assay Kit for Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay)

AT3; ATIII; SERPINC1; Anti-Thrombin Antibodies; Serpin Peptidase Inhibitor Clade C Member 1; Coding Sequence Signal Peptide Antithrombin Part 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-104 91
EDTA plasma(n=5) 80-105 90
heparin plasma(n=5) 82-91 85
sodium citrate plasma(n=5) 87-97 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-104% 99-105% 98-105% 92-99%
EDTA plasma(n=5) 98-105% 92-101% 82-103% 89-102%
heparin plasma(n=5) 87-98% 98-105% 85-104% 82-103%
sodium citrate plasma(n=5) 81-90% 80-102% 89-96% 90-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Thromb Res Thalidomide and multiple myeloma serum synergistically induce a hemostatic imbalance in endothelial cells in vitro PubMed: 25840743
Neurotherapeutics iTRAQ-Based Quantitative Proteomics Reveals the New Evidence Base for Traumatic Brain Injury Treated with Targeted Temperature Management pubmed:29247448
Journal of Clinical and Aesthetic Dermatology Detection of Angiotensin II and AT1 Receptor Concentrations in Keloid and Hypertrophic Scar.
博士论文 An Agile Approach to Novel Recombinant Antithrombin Production for use in Biologics Development
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPC313Mu02 Recombinant Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
RPC313Mu01 Recombinant Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
PAC313Mu02 Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
PAC313Mu01 Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
LAC313Mu81 FITC-Linked Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IF.
LAC313Mu71 Biotin-Linked Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC.
SEC313Mu ELISA Kit for Antithrombin (AT) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC313Mu Multiplex Assay Kit for Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSC313Mu01 ELISA Kit DIY Materials for Antithrombin (AT) Main materials for "Do It (ELISA Kit) Yourself".