Multiplex Assay Kit for Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay)

EST2; TCS1; TP2; TRT; hEST2; Telomerase catalytic subunit; Telomerase-associated protein 2

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-97 91
EDTA plasma(n=5) 84-102 91
heparin plasma(n=5) 92-101 97
sodium citrate plasma(n=5) 96-104 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-101% 80-89% 98-105% 81-98%
EDTA plasma(n=5) 98-105% 99-105% 95-105% 84-101%
heparin plasma(n=5) 90-103% 82-102% 91-101% 78-105%
sodium citrate plasma(n=5) 95-102% 99-105% 94-101% 93-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TERT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Physiological Anthropology Telomeres are elongated in rats exposed to moderate altitude Pubmed:Pmc4088304
Exp Ther Med Thymocytes maintain immune activity through telomere elongation in rats under hypoxic conditions PubMed: 26640565
Journal of Physiological Anthropology Telomere elongation protects heart and lung tissue cells from fatal damage in rats exposed to severe hypoxia Pubmed:29454386
Respiratory Medicine Coexistence of obstructive sleep apnea and telomerase activity, concentration of selected adipose tissue hormones and vascular endothelial function in patients with …
Stress Maternal neglect results in reduced telomerase activity and increased oxidative load in rats Pubmed: 32588701
INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE Reversal of brain aging by targeting telomerase: A nutraceutical approach 34515324
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APC241Hu01 Active Telomerase Reverse Transcriptase (TERT) Cell culture; Activity Assays.
RPC241Hu01 Recombinant Telomerase Reverse Transcriptase (TERT) Positive Control; Immunogen; SDS-PAGE; WB.
RPC241Hu02 Recombinant Telomerase Reverse Transcriptase (TERT) Positive Control; Immunogen; SDS-PAGE; WB.
PAC241Hu01 Polyclonal Antibody to Telomerase Reverse Transcriptase (TERT) WB; IHC; ICC; IP.
MAC241Hu22 Monoclonal Antibody to Telomerase Reverse Transcriptase (TERT) WB; IHC; ICC; IP.
SEC241Hu ELISA Kit for Telomerase Reverse Transcriptase (TERT) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC241Hu Multiplex Assay Kit for Telomerase Reverse Transcriptase (TERT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.