Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay)
COL10A1; COL10-A1; Schmid Metaphyseal Chondrodysplasia; Collagen Alpha-1(X)chain
(Note: Up to 8-plex in one testing reaction)
- Product No.LMC156Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.02-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.007 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 437
US$ 454
US$ 479
US$ 512
US$ 546
US$ 596
US$ 672
Result
For more details, please contact local distributors! US$ 840 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-101 | 82 |
EDTA plasma(n=5) | 90-101 | 94 |
heparin plasma(n=5) | 85-99 | 94 |
sodium citrate plasma(n=5) | 90-97 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-90% | 79-89% | 78-90% | 87-95% |
EDTA plasma(n=5) | 80-94% | 97-105% | 97-105% | 89-96% |
heparin plasma(n=5) | 94-103% | 82-91% | 94-102% | 90-104% |
sodium citrate plasma(n=5) | 82-95% | 94-101% | 85-95% | 88-95% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:COL10) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Tissue Eng Part A | Chondrogenic Differentiation Processes in Human Bone Marrow Aspirates upon rAAV-Mediated Gene Transfer and Overexpression of the Insulin-Like Growth Factor I PubMed: 26123891 |
Gene Ther | rAAV-mediated overexpression of sox9, TGF-β and IGF-I in minipig bone marrow aspirates to enhance the chondrogenic processes for cartilage repair PubMed: 26583804 |
American Journal of Pathology | Reduced Terminal Complement Complex Formation in Mice Manifests in Low Bone Mass and Impaired Fracture Healing Pubmed: 30339839 |
Type X Collagen Assays and Methods of Use Thereof |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPC156Hu01 | Recombinant Collagen Type X (COL10) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAC156Hu01 | Polyclonal Antibody to Collagen Type X (COL10) | WB; IHC; ICC; IP. |
LAC156Hu71 | Biotin-Linked Polyclonal Antibody to Collagen Type X (COL10) | WB; IHC; ICC. |
LAC156Hu81 | FITC-Linked Polyclonal Antibody to Collagen Type X (COL10) | WB; IHC; ICC; IF. |
MAC156Hu22 | Monoclonal Antibody to Collagen Type X (COL10) | WB; IHC; ICC; IP. |
SEC156Hu | ELISA Kit for Collagen Type X (COL10) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCC156Hu | CLIA Kit for Collagen Type X (COL10) | Chemiluminescent immunoassay for Antigen Detection. |
LMC156Hu | Multiplex Assay Kit for Collagen Type X (COL10) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSC156Hu01 | ELISA Kit DIY Materials for Collagen Type X (COL10) | Main materials for "Do It(ELISA Kit) Yourself" |