Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay)
OLR1; CLEC8A; SCARE1; Oxidized low-density lipoprotein receptor 1; C-type lectin domain family 8 member A; Lectin-like oxidized LDL receptor 1; Lectin-type oxidized LDL receptor 1
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB859Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range3.91-4000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 1.303 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 450
US$ 468
US$ 494
US$ 528
US$ 563
US$ 615
US$ 693
Result
For more details, please contact local distributors! US$ 866 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 94-101 | 98 |
EDTA plasma(n=5) | 89-98 | 93 |
heparin plasma(n=5) | 96-104 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 92-99% | 92-104% | 80-94% | 96-103% |
EDTA plasma(n=5) | 85-96% | 95-104% | 82-95% | 94-102% |
heparin plasma(n=5) | 78-94% | 95-102% | 97-105% | 85-94% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:LOX1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Clinical Cardiology | Circulating Soluble Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 Levels Are Associated With Angiographic Coronary Lesion Complexity in Patients With Coronary Artery Diseas PubMed: 21400544 |
Coronary Artery Disease | Postprocedural serum sLOX-1 levels are associated with coronary in-stent restenosis in patients with stable coronary artery disease LWW: 06000 |
Clinical Biochemistry | Soluble lectin-like oxidized low-density lipoprotein receptor-1 levels in synovial fluid are correlated with disease severity of knee osteoarthritis ScienceDirect: S0009912011004905 |
Mediators of Inflammation | Pregnancy Followed by Delivery May Affect Circulating Soluble Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 Levels in Women of Reproductive Age PubMed: 22619487 |
Dicle Medical Journal | Lectin-like oxidized low density lipoprotein receptor 1(LOX-1) levels and endothelial dysfunction in patients with primary essential hyperhidrosis/Primer esansiyel hiperhidroz hastalarinda lektin benzeri okside düsük dansiteli lipoprotein reseptor 1(LOX-1) düzeyleri ve endotel disfonksiyonu Readperiodicals: Source |
Journal of Clinical Laboratory Analysis | Soluble Lectin-Like Oxidized LDL Receptor 1 as a Possible Mediator of Endothelial Dysfunction in Patients With Metabolic Syndrome Pubmed:24798146 |
Journal of Human Hypertension | Endothelial damage in white coat hypertension: role of lectin-like oxidized low-density lipoprotein-1 Pubmed:25007999 |
Gynecologic and Obstetric Investigation | Inhibition of Lectin-Like Oxidized Low-Density Lipoprotein Receptor 1 Protects against Plasma/Hypoxia-Mediated Trophoblast Dysfunction Associated with Preeclampsia Pubmed:25633310 |
World J Gastroenterol | Increased serum soluble lectin-like oxidized low-density lipoprotein receptor-1 levels in patients with biopsy-proven nonalcoholic fatty liver disease PubMed: 26185381 |
Genetic Testing and Molecular Biomarkers | Serum sLOX-1 Levels Are Correlated with the Presence and Severity of Obstructive Sleep Apnea PubMed: 25825846 |
Neurotoxicology. | 27-Hydroxycholesterol regulates cholesterol synthesis and transport in C6 glioma cells. pubmed:28167099 |
Journal of the American Heart Association | Increased Levels of Lectin‐Like Oxidized Low‐Density Lipoprotein Receptor‐1 in Ischemic Stroke and Transient Ischemic Attack Pubmed:29330254 |
Higher serum lectin-like oxidized low-density lipoprotein receptor-1 in patients with stable coronary artery disease is associated with major adverse … | |
Disease Markers | Baseline Serum sLOX-1 Concentrations Are Associated with 2-Year Major Adverse Cardiovascular and Cerebrovascular Events in Patients after Percutaneous … Pubmed: 31772687 |
Reproductive Biology | Polycystic ovary syndrome and endothelial dysfunction: A potential role for soluble lectin-like oxidized low density lipoprotein receptor-1 Pubmed: 32409108 |
Int J Cancer | The oxidized‐LDL/LOX‐1 axis in tumor endothelial cells enhances metastasis by recruiting neutrophils and cancer cells Pubmed:35608341 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPB859Ra01 | Recombinant Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB859Ra01 | Polyclonal Antibody to Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) | WB; IHC; ICC; IP. |
MAB859Ra21 | Monoclonal Antibody to Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) | WB; IHC; ICC; IP. |
SEB859Ra | ELISA Kit for Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB859Ra | Multiplex Assay Kit for Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |