Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay)
NTN1L; Epididymis tissue protein Li 131P
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB827Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range1.95-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.65 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 415
US$ 431
US$ 455
US$ 487
US$ 519
US$ 567
US$ 638
Result
For more details, please contact local distributors! US$ 798 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 86-99 | 91 |
EDTA plasma(n=5) | 88-101 | 94 |
heparin plasma(n=5) | 83-101 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-97% | 79-89% | 87-101% | 99-105% |
EDTA plasma(n=5) | 78-101% | 97-104% | 89-103% | 82-105% |
heparin plasma(n=5) | 90-97% | 80-95% | 90-99% | 92-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:Ntn1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Transplantation Proceedings | Netrin-1: A Novel Universal Biomarker of Human Kidney Injury PubMed: 20620466 |
Biomarkers | Plasma netrin-1 is a diagnostic biomarker of human cancers PubMed: PMC3143477 |
Journal of Maternal-Fetal and Neonatal Medicine | Cord blood netrin-1 and -4 concentrations in term pregnancies with normal, restricted and increased fetal growth Informahealthcare: Source |
4 | Netrin-1 promotes adipose tissue macrophage retention and insulin resistance in obesity Pubmed:24584118 |
J Matern?Fetal?Neonatal Med.? | Cord blood netrin-1 and-4 concentrations in term pregnancies with normal, restricted and increased fetal growth Pubmed:24716747 |
Renal failure. | Urinary netrin-1 and KIM-1 as early biomarkers for septic acute kidney injury Pubmed:25154466 |
Stem Cell Research & Therapy | Netrin-1 acts as a non-canonical angiogenic factor produced by human Wharton’s jelly mesenchymal stem cells (WJ-MSC) articles:10.1186 |
Oncotarget | The effect of aspirin on circulating netrin-1 levels in humans is dependent on the inflammatory status of the vascular endothelium. pubmed:29156815 |
Frontiers in Cellular Neuroscience | Neuroprotection Exerted by Netrin-1 and Kinesin Motor KIF1A in Secondary Brain Injury following Experimental Intracerebral Hemorrhage in Rats Pubmed:29375318 |
Scientific Reports | Netrin-1 promotes diabetic corneal wound healing through molecular mechanisms mediated via the adenosine 2B receptor Pubmed:29662125 |
Family Practice and Palliative Care | Relationship of serum netrin-1 levels with breast masses Doi: 10.22391/fppc.467700 |
JOURNAL OF BIOLOGICAL CHEMISTRY | Role of microRNA in CB1 antagonist-mediated regulation of adipose tissue macrophage polarization and chemotaxis during diet-induced obesity Pubmed: 30910812 |
International Journal of Molecular Sciences | Downregulation of the Netrin-1 Receptor UNC5b Underlies Increased Placental Angiogenesis in Human Gestational Diabetes Mellitus Pubmed: 30897795 |
Cancer Biomark | Serum netrin-1 as a biomarker for colorectal cancer detection Pubmed: 32474463 |
Níveis Elevados de Netrina-1 e IL-1β em Mulheres Idosas com SCA: Pior Prognóstico no Acompanhamento de Dois Anos | |
Tuberk Toraks | Association of plasma netrin-1 level with inflammatory balance and comorbidities in patients with acute exacerbation of COPD 33853303 |
Adv Healthc Mater | Conductive Hydrogel Conduits with Growth Factor Gradients for Peripheral Nerve Repair in Diabetics with Non‐suture Tape Pubmed:35670309 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPB827Hu01 | Recombinant Netrin 1 (Ntn1) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPB827Hu02 | Recombinant Netrin 1 (Ntn1) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB827Hu01 | Polyclonal Antibody to Netrin 1 (Ntn1) | WB; IHC; ICC; IP. |
MAB827Hu22 | Monoclonal Antibody to Netrin 1 (Ntn1) | WB; IHC; ICC; IP. |
SEB827Hu | ELISA Kit for Netrin 1 (Ntn1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB827Hu | Multiplex Assay Kit for Netrin 1 (Ntn1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |