Multiplex Assay Kit for Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD321; F11R; KAT; JAM-A; JAMA; JCAM; PAM1; Coagulation Factor XI Receptor; Platelet F11 receptor; Platelet adhesion molecule 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 82-90 86
heparin plasma(n=5) 83-101 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-103% 90-101% 89-96% 93-103%
EDTA plasma(n=5) 90-98% 82-92% 91-98% 83-101%
heparin plasma(n=5) 90-104% 82-101% 95-105% 82-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:JAM1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Mediators Inflamm Early Detection of Junctional Adhesion Molecule-1 (JAM-1) in the Circulation after Experimental and Clinical Polytrauma PubMed: 26556956
JGH OPEN Cilostazol against 2, 4, 6‐trinitrobenzene sulfonic acid‐induced colitis: Effect on tight junction, inflammation, and apoptosis
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB782Hu01 Recombinant Junctional Adhesion Molecule 1 (JAM1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB782Hu01 Polyclonal Antibody to Junctional Adhesion Molecule 1 (JAM1) WB; IHC; ICC; IP.
FAB782Hu01 Anti-Junctional Adhesion Molecule 1 (JAM1) Polyclonal Antibody Flow cytometry.
MAB782Hu22 Monoclonal Antibody to Junctional Adhesion Molecule 1 (JAM1) WB; IHC; ICC; IP.
MAB782Hu21 Monoclonal Antibody to Junctional Adhesion Molecule 1 (JAM1) WB; IHC; ICC; IP.
MAB782Hu23 Monoclonal Antibody to Junctional Adhesion Molecule 1 (JAM1) WB; IHC; ICC; IP.
SEB782Hu ELISA Kit for Junctional Adhesion Molecule 1 (JAM1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB782Hu Multiplex Assay Kit for Junctional Adhesion Molecule 1 (JAM1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.