Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay)
CD206; CLEC13D, CLEC13DL, MRC1L1; C-type lectin domain family 13 member D-like; Macrophage mannose receptor 1-like protein 1
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB542Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.02-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.007 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 415
US$ 431
US$ 455
US$ 487
US$ 519
US$ 567
US$ 638
Result
For more details, please contact local distributors! US$ 798 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 85-92 | 88 |
EDTA plasma(n=5) | 84-92 | 88 |
heparin plasma(n=5) | 78-89 | 83 |
sodium citrate plasma(n=5) | 80-88 | 80 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-102% | 88-95% | 79-102% | 92-105% |
EDTA plasma(n=5) | 92-102% | 91-99% | 95-103% | 89-98% |
heparin plasma(n=5) | 80-102% | 99-105% | 85-101% | 80-101% |
sodium citrate plasma(n=5) | 83-97% | 80-89% | 92-105% | 88-96% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:MRC1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
PLoS One | Spatiotemporal Cadence of Macrophage Polarisation in a Model of Light-Induced Retinal Degeneration PubMed: 26630454 |
Parasite Immunology | KLF4 upregulation is involved in alternative macrophage activation during secondary Echinococcus granulosus infection Pubmed: 31407814 |
Inflammation | Toll-Like Receptor 2–Mediated Autophagy Promotes Microglial Cell Death by Modulating the Microglial M1/M2 Phenotype Pubmed: 31834572 |
International Journal of Clinical and Experimental Medicine | The phenotypical induction and damage effect of peptidoglycan on microglia |
Neurochem Res | Protective Effect of Mild Hypothermia on Spinal Cord Ischemia-Induced Delayed Paralysis and Spinal Cord Injury Pubmed:34993705 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPB542Hu01 | Recombinant Mannose Receptor C Type 1 (MRC1) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB542Hu01 | Polyclonal Antibody to Mannose Receptor C Type 1 (MRC1) | WB; IHC; ICC; IP. |
MAB542Hu22 | Monoclonal Antibody to Mannose Receptor C Type 1 (MRC1) | WB; IHC; ICC; IP. |
SEB542Hu | ELISA Kit for Mannose Receptor C Type 1 (MRC1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB542Hu | Multiplex Assay Kit for Mannose Receptor C Type 1 (MRC1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |