Multiplex Assay Kit for Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay)

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-101 95
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 89-101 93
sodium citrate plasma(n=5) 82-101 86

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 89-102% 83-101% 84-101%
EDTA plasma(n=5) 84-97% 98-105% 91-101% 93-101%
heparin plasma(n=5) 87-105% 81-88% 78-104% 84-105%
sodium citrate plasma(n=5) 90-98% 81-91% 80-92% 88-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:OVA) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Vaccine. Non-invasive delivery of nanoparticles to hair follicles: A perspective for transcutaneous immunization Pubmed: 23290836
Cell Biology International Alphavbeta6 is required in maintaining the intestinal epithelial barrier function Pubmed:24677750
MAbs Characterization of a novel anti-human lymphocyte activation gene 3 (LAG-3) antibody for cancer immunotherapy Pubmed: 31242068
Materials Science and Engineering: C Double-responsive hyaluronic acid-based prodrugs for efficient tumour targeting 34857264
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
NPB459Ge01 Native Ovalbumin (OVA) Positive Control; Immunogen; SDS-PAGE; WB.
PAB459Ge01 Polyclonal Antibody to Ovalbumin (OVA) WB; IHC; ICC; IP.
LAB459Ge71 Biotin-Linked Polyclonal Antibody to Ovalbumin (OVA) WB; IHC; ICC.
MAB459Ge21 Monoclonal Antibody to Ovalbumin (OVA) WB
MAB459Ge24 Monoclonal Antibody to Ovalbumin (OVA) WB; IHC; ICC; IP.
MAB459Ge23 Monoclonal Antibody to Ovalbumin (OVA) WB; IHC; ICC; IP.
MAB459Ge25 Monoclonal Antibody to Ovalbumin (OVA) WB
MAB459Ge22 Monoclonal Antibody to Ovalbumin (OVA) WB; IHC; ICC; IP.
HEB459Ge High Sensitive ELISA Kit for Ovalbumin (OVA) Enzyme-linked immunosorbent assay for Antigen Detection.
SEB459Ge ELISA Kit for Ovalbumin (OVA) Enzyme-linked immunosorbent assay for Antigen Detection.
CEB459Ge ELISA Kit for Ovalbumin (OVA) Enzyme-linked immunosorbent assay for Antigen Detection.
AEB459Ge ELISA Kit for Anti-Ovalbumin Antibody (Anti-OVA) Enzyme-linked immunosorbent assay for Antibody Detection.
CCB459Ge CLIA Kit for Ovalbumin (OVA) Chemiluminescent immunoassay for Antigen Detection.
LMB459Ge Multiplex Assay Kit for Ovalbumin (OVA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB459Ge11 ELISA Kit DIY Materials for Ovalbumin (OVA) Main materials for "Do It (ELISA Kit) Yourself".