Multiplex Assay Kit for Integrin Alpha V (ITGaV) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD51; ITG-AV; MSK8; VNRA; Vitronectin Receptor,Alpha Polypeptide

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Integrin Alpha V (ITGaV) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Integrin Alpha V (ITGaV) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Integrin Alpha V (ITGaV) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Integrin Alpha V (ITGaV) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ITGaV) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Global Pharma Technology Vitronectin, Integrin Vitronectin Receptor Other Biochemical Markers to Assess the Development of Liver Cirrhosis ISSN: 0975 -8542
EJNMMI Research PET imaging of Ga-NODAGA-RGD, as compared with F-fluorodeoxyglucose, in experimental rodent models of engrafted glioblastoma Pubmed:29904818
Biomaterials Mechanically induced formation and maturation of 3D-matrix adhesions (3DMAs) in human mesenchymal stem cells Pubmed: 32818825
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB282Hu01 Recombinant Integrin Alpha V (ITGaV) Positive Control; Immunogen; SDS-PAGE; WB.
RPB282Hu02 Recombinant Integrin Alpha V (ITGaV) Positive Control; Immunogen; SDS-PAGE; WB.
PAB282Hu01 Polyclonal Antibody to Integrin Alpha V (ITGaV) WB
PAB282Hu02 Polyclonal Antibody to Integrin Alpha V (ITGaV) WB; IHC; ICC; IP.
MAB282Hu21 Monoclonal Antibody to Integrin Alpha V (ITGaV) WB; IHC; ICC; IP.
MAB282Hu23 Monoclonal Antibody to Integrin Alpha V (ITGaV) WB; IHC; ICC; IP.
MAB282Hu22 Monoclonal Antibody to Integrin Alpha V (ITGaV) WB; IHC; ICC; IP.
MAB282Hu24 Monoclonal Antibody to Integrin Alpha V (ITGaV) WB; IHC; ICC; IP.
MAB282Hu25 Monoclonal Antibody to Integrin Alpha V (ITGaV) WB; IHC; ICC; IP.
FAB282Hu82 FITC-Linked Anti-Integrin Alpha V (ITGaV) Monoclonal Antibody FCM
SEB282Hu ELISA Kit for Integrin Alpha V (ITGaV) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB282Hu Multiplex Assay Kit for Integrin Alpha V (ITGaV) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.