Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay)
GC; GLP1; GLP2; GRPP; Glicentin-Related Polypeptide; Glucagen; Oxyntomodulin; Incretin hormone
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB266Ga
- Organism SpeciesChicken (Gallus) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range1.46-1500pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.487 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 450
US$ 468
US$ 494
US$ 528
US$ 563
US$ 615
US$ 693
Result
For more details, please contact local distributors! US$ 866 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 94-102 | 97 |
EDTA plasma(n=5) | 99-105 | 102 |
heparin plasma(n=5) | 87-95 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 93-103% | 88-104% | 83-101% | 92-104% |
EDTA plasma(n=5) | 81-92% | 90-99% | 99-105% | 91-104% |
heparin plasma(n=5) | 99-105% | 93-101% | 84-93% | 80-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:GCG) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Molecular Metabolism | PER2 promotes glucose storage to liver glycogen during feeding and acute fasting by inducing Gys2 PTG and GL expression PubMed: PMC3773838 |
Exp Biol Med (Maywood). | Increasing glucagon secretion could antagonize the action of exogenous insulin for glycemic control in streptozocin-induced diabetic rhesus monkeys. Pubmed: 23760004 |
European Journal of Endocrinology | Specificity and sensitivity of commercially available assays for glucagon and oxyntomodulin measurement in human Eje-online: Source |
American Diabetes Association | IL-21 is a major negative regulator of IRF4-dependent lipolysis affecting Tregs in adipose tissue and systemic insulin sensitivity Pubmed:24430438 |
Journal of Pharmacy and Pharmacology | Enzogenol improves diabetes-related metabolic change in C57BL/KsJ-db/db?mice, a model of type 2 diabetes mellitus Pubmed:24611864 |
European Journal of Pharmacology | Subcutaneous administration of liraglutide ameliorates learning and memory impairment by modulating tau hyperphosphorylation via the glycogen synthase kinase-3尾 pathway in an amyloid 尾 protein induced alzheimer disease mouse model Pubmed:27131827 |
Appl Physiol Nutr Metab | The glucoreCavia (Guinea pig )latory response to high-intensity aerobic exercise following training in rats with insulin-treated type 1 diabetes mellitus Pubmed:27175938 |
American Journal of Translational Research | Subcutaneous liraglutide ameliorates methylglyoxal-induced Alzheimer-like tau pathology and cognitive impairment by modulating tau hyperphosphorylation and glycogen synthase kinase-3β. pubmed:28337257 |
Biomedicine & Pharmacotherapy | Vitamin D3 intake as regulator of insulin degrading enzyme and insulin receptor phosphorylationin diabetic rats. pubmed:27930980 |
Diabetologia | Ginsenoside Rg5 attenuates hepatic glucagon response via suppression of succinate-associated HIF-1α induction in HFD-fed mice pubmed:28280902 |
International Journal of Molecular Sciences | Effects of Acute Cold Stress on Liver O-GlcNAcylation and Glycometabolism in Mice Pubmed: 30231545 |
European Journal of Pharmacology | Exogenous obestatin decreases beta-cell apoptosis and alfa-cell proliferation in high fat diet and streptozotocin induced type 2 diabetic rats Pubmed: 30776368 |
Stress | Regulating glycolysis, the TLR4 signal pathway and expression of RBM3 in mouse liver in response to acute cold exposure Pubmed: 30821572 |
international journal of molecular sciences | Effects of Cold-inducible RNA-binding Protein (CIRP) on Liver Glycolysis during Acute Cold Exposure in C57BL/6 Mice Pubmed: 30909542 |
Diabetes-Metabolism Research and Reviews | Liraglutide Combined with Human Umbilical Cord Mesenchymal Stem Cell Transplantation inhibits beta‐cells apoptosis via mediating the ASK1/JNK/BAX pathway in Pubmed: 31411368 |
CELL DISCOVERY | In vitro expansion of pancreatic islet clusters facilitated by hormones and chemicals Pubmed: 32284878 |
endocrine journal | Mice with nucleus tractus solitarius injury induced by chronic restraint stress present impaired ability to raise blood glucose and glucagon levels when blood glucose … Pubmed: 32249244 |
Frontiers in Endocrinology | RFRP-3, the Mammalian Ortholog of GnIH, Is a Novel Modulator Involved in Food Intake and Glucose Homeostasis Pubmed: 32328034 |
Molecular Medicine Reports | Acarbose ameliorates spontaneous type‑2 diabetes in db/db mice by inhibiting PDX‑1 methylation Pubmed: 33236139 |
CHEMICO-BIOLOGICAL INTERACTIONS | Modulatory role of imatinib mesylate on pancreatic β-cells' secretory functions in an STZ rat model of diabetes mellitus Pubmed: 32710900 |
Mol Cell Endocrinol | Mof acetyltransferase inhibition ameliorates glucose intolerance and islet dysfunction of type 2 diabetes via targeting pancreatic α-cells 34391847 |
Catalog No. | Related products for research use of Chicken (Gallus) Organism species | Applications (RESEARCH USE ONLY!) |
RPB266Ga01 | Recombinant Glucagon (GCG) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB266Ga01 | Polyclonal Antibody to Glucagon (GCG) | WB; IHC; ICC; IP. |
MAB266Ga21 | Monoclonal Antibody to Glucagon (GCG) | WB; IHC; ICC; IP. |
CEB266Ga | ELISA Kit for Glucagon (GCG) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB266Ga | Multiplex Assay Kit for Glucagon (GCG) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |