Multiplex Assay Kit for Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay)

RLXH1; Relaxin H1; Prorelaxin H1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 92-104 96
heparin plasma(n=5) 88-101 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-104% 78-91% 92-105% 94-102%
EDTA plasma(n=5) 90-102% 85-92% 96-104% 89-97%
heparin plasma(n=5) 98-105% 86-94% 95-104% 86-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:RLN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Reproducao & Climatério Culture of human granulosa cells with follicular phase phenotype: influence of chemically defined system on morphology, ultrastructure, secretion of steroids and relaxin ScienceDirect: S1413208713000034
BioMed Research International Upregulation of Relaxin after Experimental Subarachnoid Hemorrhage in Rabbits Pubmed:25133183
Advanced Healthcare Materials Impact of Hydrogel Elasticity and Adherence on Osteosarcoma Cells and Osteoblasts Pubmed: 30838809
Catalog No. Related products for research use of Sus scrofa; Porcine (Pig) Organism species Applications (RESEARCH USE ONLY!)
RPB216Po01 Recombinant Relaxin (RLN) Positive Control; Immunogen; SDS-PAGE; WB.
PAB216Po01 Polyclonal Antibody to Relaxin (RLN) WB; IHC; ICC; IP.
MAB216Po21 Monoclonal Antibody to Relaxin (RLN) WB; IHC; ICC; IP.
CEB216Po ELISA Kit for Relaxin (RLN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB216Po Multiplex Assay Kit for Relaxin (RLN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.