Multiplex Assay Kit for Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay)

PYY1; Peptide tyrosine tyrosine

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-102 98
EDTA plasma(n=5) 96-105 102
heparin plasma(n=5) 80-94 84
sodium citrate plasma(n=5) 88-99 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-104% 93-101% 82-98% 79-93%
EDTA plasma(n=5) 88-96% 85-99% 86-98% 95-102%
heparin plasma(n=5) 79-93% 83-102% 80-101% 98-105%
sodium citrate plasma(n=5) 88-98% 80-101% 90-97% 89-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PYY) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
International Journal of Sport Studies The Effects of Concurrent Resistance and Endurance Exercise on Hunger Feelings and PYY in Obese Men Com:Source
Annals of Applied Sport Science Effect of an Acute Incremental Exercise on Plasma Peptide YY, Neuropeptide Y and IGF-1 Concentrations in Young Athletes Aassjournal:Source
Biomedical Reports Calprotectin in serum and zonulin in serum and feces are elevated after introduction of a diet with lower carbohydrate content and higher fiber, fat and protein contents. pubmed:28413639
Acta Diabetologica Effect of lifestyle improvement program on the biomarkersof adiposity, inflammation and gut hormones in overweight/obese Asian Indians with prediabetes pubmed:28620678
Biomedical Reports Calprotectin in serum and zonulin in serum and feces are elevated after introduction of a diet with lower carbohydrate content and higher fiber, fat and protein contents 10.3892/br.2017.865
Journal of Diabetes & Metabolism High Fiber Fat and Protein Contents Lead to Increased Satiety Reduced Sweet Cravings and Decreased Gastrointestinal Symptoms Independently of Anthropometric Hormonal and Metabolic Factors 10.4172/2155-6156.1000733 
Frontiers in Physiology Ileal Transposition Surgery Decreases Fat Mass and Improves Glucose Metabolism in Diabetic GK Rats: Possible Involvement of FGF21 Pubmed:29593555
Food and Nutrition Research Alignments of endocrine, anthropometric, and metabolic parameters in type 2 diabetes after intervention with an Okinawa-based Nordic diet Pubmed:29599686
The Journal of Nutrition Grape Seed Proanthocyanidin Affects Lipid Metabolism via Changing Gut Microflora and Enhancing Propionate Production in Weaned Pigs Pubmed: 31175811
The Journal of Nutritional Biochemistry Bile acid receptor TGR5 is critically involved in preference for dietary lipids and obesity Pubmed: 31812910
Arch Toxicol Serotonin involvement in okadaic acid-induced diarrhoea in vivo 34148100
foods Appetite and Satiety Effects of the Acute and Regular Consumption of Green Coffee Phenols and Green Coffee Phenol/Oat β-Glucan Nutraceuticals in Subjects with … 34828792
Catalog No. Related products for research use of Sus scrofa; Porcine (Pig) Organism species Applications (RESEARCH USE ONLY!)
RPB067Po01 Recombinant Peptide YY (PYY) Positive Control; Immunogen; SDS-PAGE; WB.
CPB067Po21 OVA Conjugated Peptide YY (PYY) Immunogen; SDS-PAGE; WB.
PAB067Po01 Polyclonal Antibody to Peptide YY (PYY) WB; IHC; ICC; IP.
MAB067Po21 Monoclonal Antibody to Peptide YY (PYY) WB; IHC; ICC; IP.
CEB067Po ELISA Kit for Peptide YY (PYY) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB067Po Multiplex Assay Kit for Peptide YY (PYY) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.