Multiplex Assay Kit for Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay)
PDCD8; Programmed Cell Death protein 8; Apoptosis-inducing factor 1, mitochondrial
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB064Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 450
US$ 468
US$ 494
US$ 528
US$ 563
US$ 615
US$ 693
Result
For more details, please contact local distributors! US$ 866 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 91-98 | 95 |
EDTA plasma(n=5) | 87-101 | 97 |
heparin plasma(n=5) | 96-104 | 101 |
sodium citrate plasma(n=5) | 83-90 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-104% | 91-105% | 81-90% | 90-99% |
EDTA plasma(n=5) | 94-105% | 92-102% | 82-96% | 89-103% |
heparin plasma(n=5) | 85-103% | 80-101% | 81-93% | 83-92% |
sodium citrate plasma(n=5) | 90-101% | 79-103% | 93-102% | 85-92% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:AIF) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
РОЛЬ АПОПТОЗ ИНДУЦИРУЮЩЕГО ФАКТОРА И ОКИСЛИТЕЛЬНОГО СТРЕССА ПРИ ХРОНИЧЕСКОЙ СЕРДЕЧНОЙ НЕДОСТАТОЧНОСТИ 616-005.8 | |
NEUROCHEMISTRY INTERNATIONAL | Redox-active DJ-1 sustains brainstem cardiovascular regulation via maintenance of mitochondrial function during mevinphos intoxication Pubmed: 32650030 |
Iranian Journal of Basic Medical Sciences | Chromon-3-aldehyde derivatives restore mitochondrial function in rat cerebral ischemia Pubmed: 32963739 |
Journal of?Pharmaceutical Sciences | Correction of mitochondrial dysfunction by 4-hydroxy-3, 5-ditretbutyl cinnamic acid in experimental Alzheimer's disease induced by A¦Â injection in rats. |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPB064Ra01 | Recombinant Apoptosis Inducing Factor (AIF) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB064Ra01 | Polyclonal Antibody to Apoptosis Inducing Factor (AIF) | WB; IHC; ICC; IP. |
MAB064Ra21 | Monoclonal Antibody to Apoptosis Inducing Factor (AIF) | WB; IHC; ICC; IP. |
SEB064Ra | ELISA Kit for Apoptosis Inducing Factor (AIF) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB064Ra | Multiplex Assay Kit for Apoptosis Inducing Factor (AIF) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |