Multiplex Assay Kit for Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay)

CYP7; CYP7-A1; CYPVII; Cholesterol 7 Alpha Hydroxylase; Cytochrome P450 Family 7 Subfamily A Polypeptide 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-96 92
EDTA plasma(n=5) 93-101 97
heparin plasma(n=5) 86-94 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-99% 79-99% 97-105% 95-103%
EDTA plasma(n=5) 81-93% 94-102% 78-90% 94-101%
heparin plasma(n=5) 80-91% 81-97% 82-99% 90-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CYP7A1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Cell Reports Parabacteroides distasonis Alleviates Obesity and Metabolic Dysfunctions via Production of Succinate and Secondary Bile Acids Pubmed: 30605678
Journal of Functional Foods Hyperglycemia exacerbates dyslipidemia-induced changes in uptake, synthesis, and transporters of bile acids in rats: Assessment of restorative potentials of ALA and?… Doi: 10.1016/j.jff.2019.01.038
Journal of Agriculture and Food Research Withaferin-A down-regulate enterohepatic circulation of bile acids: An insight from a hyperlipidemic rat model
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB053Hu01 Recombinant Cytochrome P450 7A1 (CYP7A1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB053Hu01 Polyclonal Antibody to Cytochrome P450 7A1 (CYP7A1) WB; IHC; ICC; IP.
MAB053Hu22 Monoclonal Antibody to Cytochrome P450 7A1 (CYP7A1) WB; IHC; ICC; IP.
SEB053Hu ELISA Kit for Cytochrome P450 7A1 (CYP7A1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB053Hu Multiplex Assay Kit for Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.