Multiplex Assay Kit for Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay)

MAPK1; P38; P40; ERK2; ERT1; MAPK2; P42MAPK; P42-MAPK; PRKM1; PRKM2; P41; P41mapk; P41-mapk; Mitogen-Activated Protein Kinase 1; Mitogen-activated protein kinase 2

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-103 92
EDTA plasma(n=5) 97-104 101
heparin plasma(n=5) 91-99 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-97% 81-102% 82-97% 92-101%
EDTA plasma(n=5) 92-99% 85-103% 97-104% 80-96%
heparin plasma(n=5) 80-90% 94-105% 96-105% 94-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ERK2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Cellular and Molecular Neurobiology Hypericum Perforatum Hydroalcoholic Extract Mitigates Motor Dysfunction and is Neuroprotective in Intrastriatal 6-Hydroxydopamine Rat Model of Parkinson’s Disease Pubmed:26119304
Graefe's Archive for Clinical and Experimental Ophthalmology Role of RhoA/MERK1/ERK1/2/iNOS signaling in ocular ischemic syndrome pubmed:27538909
International Journal of Reproductive Medicine Gonadotropin Stimulation Has Only a Limited Effect on the Concentration of Follicular Fluid Signalling Proteins: An Antibody Array Analysis 33575317
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA930Ra01 Recombinant Extracellular Signal Regulated Kinase 2 (ERK2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA930Ra01 Polyclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
MAA930Ra21 Monoclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
SEA930Ra ELISA Kit for Extracellular Signal Regulated Kinase 2 (ERK2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA930Ra Multiplex Assay Kit for Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.