Multiplex Assay Kit for Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay)

TP53; LFS1; TRP53; Li-Fraumeni Syndrome; Cellular tumor antigen p53; Antigen NY-CO-13; Phosphoprotein p53; Tumor suppressor p53

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-101 92
EDTA plasma(n=5) 80-91 87
heparin plasma(n=5) 80-92 79

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 92-105% 97-105% 92-101%
EDTA plasma(n=5) 86-99% 82-96% 92-101% 78-98%
heparin plasma(n=5) 80-92% 89-96% 85-95% 84-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:P53) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Anticancer Research Analysis of p53 and miRNA expression after irradiation of glioblastoma cell lines PubMed: 23155233
Microscopy Research and Technique Therapeutic role of curcumin in oxidative DNA damage caused by formaldehyde PubMed: 25761397
J Nutr Biochem Supplementation with Selenium yeast on the prooxidant–antioxidant activities and anti-tumor effects in breast tumor xenograft-bearing mice PubMed: 26344777
Biochemical and Biophysical Research Communications Transcription factor HBP1: A regulator of senescence and apoptosis of preadipocytes Pubmed: 31331641
Folia Biologica Effect of Graviola (Annona Muricata l.) and Ginger (Zingiber Officinale Roscoe) on Diabetes Mellitus Induced in Male Wistar Albino Rats
Non-POU Domain-Containing Octamer-Binding (NONO) Protein Stability Regulated by PIN1 is Crucial for Breast Cancer Tumorigenicity Via the MAPK/β …
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA928Hu01 Recombinant Tumor Protein p53 (P53) Positive Control; Immunogen; SDS-PAGE; WB.
RPA928Hu02 Recombinant Tumor Protein p53 (P53) Positive Control; Immunogen; SDS-PAGE; WB.
RPA928Hu03 Recombinant Tumor Protein p53 (P53) Positive Control; Immunogen; SDS-PAGE; WB.
APA928Hu01 Active Tumor Protein p53 (P53) Cell culture; Activity Assays.
PAA928Hu01 Polyclonal Antibody to Tumor Protein p53 (P53) WB; IHC; ICC/IF
PAA928Hu02 Polyclonal Antibody to Tumor Protein p53 (P53) WB; IHC; ICC; IP; FCM
LAA928Hu71 Biotin-Linked Polyclonal Antibody to Tumor Protein p53 (P53) WB; IHC; ICC.
MAA928Hu22 Monoclonal Antibody to Tumor Protein p53 (P53) WB
MAA928Hu24 Monoclonal Antibody to Tumor Protein p53 (P53) WB; IHC; ICC; IP.
MAA928Hu25 Monoclonal Antibody to Tumor Protein p53 (P53) WB; IHC; ICC; IP.
MAA928Hu27 Monoclonal Antibody to Tumor Protein p53 (P53) WB; IHC; ICC; IP.
MAA928Hu21 Monoclonal Antibody to Tumor Protein p53 (P53) WB; IHC; ICC; IP.
MAA928Hu23 Monoclonal Antibody to Tumor Protein p53 (P53) WB; IHC; ICC; IP.
FAA928Hu04 Anti-Tumor Protein p53 (P53) Monoclonal Antibody Flow cytometry.
FAA928Hu02 Anti-Tumor Protein p53 (P53) Monoclonal Antibody Flow cytometry.
SEA928Hu ELISA Kit for Tumor Protein p53 (P53) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA928Hu CLIA Kit for Tumor Protein p53 (P53) Chemiluminescent immunoassay for Antigen Detection.
LMA928Hu Multiplex Assay Kit for Tumor Protein p53 (P53) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA928Hu01 ELISA Kit DIY Materials for Tumor Protein p53 (P53) Main materials for "Do It (ELISA Kit) Yourself".