Multiplex Assay Kit for Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay)

Adrenaline

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-102 94
EDTA plasma(n=5) 93-101 96
heparin plasma(n=5) 89-96 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-97% 80-96% 91-99% 83-95%
EDTA plasma(n=5) 85-105% 98-105% 88-101% 90-97%
heparin plasma(n=5) 78-95% 79-91% 78-94% 90-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:EPI) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
European Patent Application EP2371376 METHODS AND REAGENTS FOR THE DIAGNOSIS, PREVENTION AND TREATMENT OF INSULIN RESISTANCE FPO:EO237136
Cardiovasc Diabetol Glibenclamide attenuates myocardial injury by lipopolysaccharides in streptozotocin-induced diabetic mice Pubmed:Pmc4147163
Autonomic Neuroscience Study of baicalin on sympathoexcitation induced by myocardial ischemia via P2X3 receptor in superior cervical ganglia Pubmed:25554221
Neuropsychiatr Dis Treat Catha edulis chewing effects on treatment of paranoid schizophrenic patients PubMed: 25926735
PLoS One Ablation of Potassium-Chloride Cotransporter Type 3 (Kcc3) in Mouse Causes Multiple Cardiovascular Defects and Isosmotic Polyuria Pubmed:27166674
Scientific Reports Reduced lipolysis response to adipose afferent reflex involved in impaired activation of adrenoceptor-cAMP-PKA-hormone sensitive lipase pathway in obesity pubmed:27694818
International Journal of Nursing Practice Non‐pharmacological interventions during childbirth for pain relief, anxiety, and neuroendocrine stress parameters: A randomized controlled trial Pubmed:29512230
Serbian Journal of Experimental and Clinical Research Assessment of the TDCS Influence on Stress-Induced Disorders in Rats with Low Stress Sustainability and Endurance
Frontiers in Endocrinology RFRP-3, the Mammalian Ortholog of GnIH, Is a Novel Modulator Involved in Food Intake and Glucose Homeostasis Pubmed: 32328034
Nature Feeding induces cholesterol biosynthesis via the mTORC1–USP20–HMGCR axis Pubmed: 33177714
Blockade of adrenergic β‐receptor activation through local delivery of propranolol from a 3D collagen/polyvinyl alcohol/hydroxyapatite scaffold promotes bone repair …
Anti-stress activity of some plants extracts of the North Caucasus flora
Mol Metab Adipose tissue lipolysis is regulated by PAQR11 via altering protein stability of phosphodiesterase 4D 33549845
CRYOBIOLOGY O-GlcNAc/Akt pathway regulates glucose metabolism and reduces apoptosis in liver of piglets with acute cold stress 33651993
Hypertension Expression of LHCGR (Luteinizing Hormone/Chorionic Gonadotrophin Receptor) in Pheochromocytomas Unveils an Endocrine Mechanism Connecting Pregnancy … Pubmed:35189708
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
CPA858Ge11 BSA Conjugated Epinephrine (EPI) Immunogen; SDS-PAGE; WB.
CPA858Ge21 OVA Conjugated Epinephrine (EPI) Immunogen; SDS-PAGE; WB.
PAA858Ge01 Polyclonal Antibody to Epinephrine (EPI) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA858Ge26 Monoclonal Antibody to Epinephrine (EPI) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA858Ge25 Monoclonal Antibody to Epinephrine (EPI) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA858Ge22 Monoclonal Antibody to Epinephrine (EPI) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
CEA858Ge ELISA Kit for Epinephrine (EPI) Enzyme-linked immunosorbent assay for Antigen Detection.
IEA858Ge Instant ELISA Kit for Epinephrine (EPI) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA858Ge High Sensitive ELISA Kit for Epinephrine (EPI) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA858Ge Mini Samples ELISA Kit for Epinephrine (EPI) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA858Ge Multiplex Assay Kit for Epinephrine (EPI) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA858Ge11 ELISA Kit DIY Materials for Epinephrine (EPI) Main materials for "Do It (ELISA Kit) Yourself".