Multiplex Assay Kit for Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay)

CA-II; CAII; Car2; CAC; Carbonate dehydratase II; Carbonic anhydrase C

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-98 95
EDTA plasma(n=5) 86-104 91
heparin plasma(n=5) 81-90 85

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-95% 78-97% 83-102% 97-105%
EDTA plasma(n=5) 96-104% 91-99% 78-88% 86-101%
heparin plasma(n=5) 95-102% 82-97% 96-105% 78-91%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CA2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Proteomics Clin Appl.  Identification of potential breast cancer markers in nipple discharge by protein profile analysis using two-dimensional nano-liquid chromatography/nanoelectrospray ionization-mass spectrometry. Pubmed:26970563
PROTEOMICS - Clinical Applications Comparative mass spectrometric and immunoassay-based proteome analysis in serum ofDuchenne muscular dystrophy patients. pubmed:26680509
Cell & Molecular Biology Identification of potential breast cancer markers in nipple discharge by protein profile analysis using two‐dimensional nano‐liquid chromatography/nanoelectrospray … doi:10.1002
Catalog No. Related products for research use of Rhesus monkey (Simian) Organism species Applications (RESEARCH USE ONLY!)
NPA782Si01 Native Carbonic Anhydrase II (CA2) Positive Control; Immunogen; SDS-PAGE; WB.
RPA782Si01 Recombinant Carbonic Anhydrase II (CA2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA782Si02 Polyclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC; IP.
PAA782Si01 Polyclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC; IP.
LAA782Si71 Biotin-Linked Polyclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC.
LAA782Si91 HRP-Linked Polyclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC.
MAA782Si22 Monoclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC; IP.
MAA782Si21 Monoclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC; IP.
SEA782Si ELISA Kit for Carbonic Anhydrase II (CA2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA782Si Multiplex Assay Kit for Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA782Si01 ELISA Kit DIY Materials for Carbonic Anhydrase II (CA2) Main materials for "Do It (ELISA Kit) Yourself".